EUVIMEDEUVIMED entdecken
Crossref

Condition Dependence of Ion‐Exchange‐Related Retention in Hydrophilic Interaction Liquid Chromatography (HILIC): Revisiting the HILIC Test Scheme

Tomoaki Shimpo, Tohru Ikegami

Journal of Separation Science · 2026-11 · 49 (11)

DOI: 10.1002/jssc.70578 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Separation Science, online erschienen am 13.11.2026. Verfasst von Tomoaki Shimpo und 1 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Molecular Chemistry and Engineering, Kyoto Institute of Technology, Kyoto, Japan. Die Arbeit nennt 52 Literaturangaben. Gefördert von: JSPS KAKENHI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Current HILIC column characterization tests rely on empirical retention selectivity descriptors, yet their robustness and physicochemical meaning remain insufficiently understood. To clarify the factors governing these descriptors, ten commercially available and home‐made HILIC columns were evaluated under five acetonitrile/aqueous mobile‐phase conditions differing in pH, buffer composition (ammonium formate or ammonium acetate), ionic species, and ionic strength. Ion‐exchange‐related retention selectivity, α ( N,N,N ‐trimethylphenylammonium chloride/uridine (U)) and α (sodium p ‐toluenesulfonate/U), showed substantial variation (CVs of 0.12–0.77), indicating limited robustness under varying mobile‐phase conditions and strong sensitivity to cation species and concentration. These factors were influenced not only by pH but also by ionic composition, reflecting changes in ionic shielding and the extent of the water‐enriched layer. Differences in buffer preparation also resulted in variations in retention behavior at identical nominal pH, highlighting the importance of controlling ionic composition for reproducible HILIC measurements. The descriptor α (theobromine (Tb)/theophylline (Tp)), commonly interpreted as a marker of the local acid–base environment of the stationary phase, exhibited systematic but nonuniform behavior (CVs of 0.01–0.26). Analysis revealed that this variation is mainly governed by the response of Tp, whereas Tb remains comparatively insensitive, indicating that α (Tb/Tp) reflects a probe‐ and condition‐dependent balance of retention mechanisms rather than a single intrinsic surface property. To further probe acid–base‐related interactions, fluorinated uridine derivatives were introduced as alternative probes. The retention selectivity α (U/5‐fluorouridine) and α (2′‐deoxyuridine/2′‐deoxy‐5‐fluorouridine) showed systematic dependence on pH and stationary phase (CVs of 0.01–0.50), as well as strong correlations with α (Tb/Tp), while providing a broader dynamic range. These findings suggest that fluorine substitution may facilitate the detection of acid–base‐related interactions on the stationary phase compared with α (Tb/Tp). Ion‐exchange‐related probes resulted in low robustness in terms of their retention and the corresponding selectivity due to differences in the nature (cation concentration and pH) of the aqueous buffer added to the mobile phases.

Schlagwörter

Stichwörter der Autor:innen

5‐fluorouridineCation exchange/Anion exchangehydrophilic interaction liquid chromatographyselectivitytheobromine/theophylline

Autor:innen und Institutionen

  • Faculty of Molecular Chemistry and Engineering, Kyoto Institute of Technology, Kyoto, Japan.
  • LC Business Unit of Life Science Business Department, Analytical and Measuring Instruments Division, Shimadzu Corporation, Kyoto, Japan.

Förderung

  • JSPS KAKENHI

Zitieren

APA

Shimpo, T., & Ikegami, T. (2026). Condition Dependence of Ion‐Exchange‐Related Retention in Hydrophilic Interaction Liquid Chromatography (HILIC): Revisiting the HILIC Test Scheme. Journal of Separation Science, 49(11). https://doi.org/10.1002/jssc.70578

Vancouver

Shimpo T, Ikegami T. Condition Dependence of Ion‐Exchange‐Related Retention in Hydrophilic Interaction Liquid Chromatography (HILIC): Revisiting the HILIC Test Scheme. Journal of Separation Science. 2026;49(11). doi:10.1002/jssc.70578

BibTeX
@article{Shimpo2026,
  author = {Shimpo, Tomoaki and Ikegami, Tohru},
  title = {Condition Dependence of Ion‐Exchange‐Related Retention in Hydrophilic Interaction Liquid Chromatography (HILIC): Revisiting the HILIC Test Scheme},
  journal = {Journal of Separation Science},
  year = {2026},
  volume = {49},
  number = {11},
  doi = {10.1002/jssc.70578}
}
Kostenlos starten →