Cold‐Induced Phase Separation Coupled With High‐Performance Liquid Chromatography‐Fluorescence Detection for Determination of Glyphosate, Aminomethylphosphonic Acid, and Glufosinate in Environmental Water
Journal of Separation Science · 2026-03 · 49 (3)
DOI: 10.1002/jssc.70399 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Separation Science, online erschienen am 26.03.2026. Verfasst von Chaonan Huang und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Environmental & Municipal Engineering, Qingdao University of Technology, Qingdao, China. Hauptthemen laut MEDLINE: Chromatography, High Pressure Liquid, Glyphosate, Organophosphonates, Aminobutyrates. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shandong Province.
Abstract (Originalsprache)
Glyphosate (GLP) and glufosinate (GLU) are among the most widely used herbicides; however, the strong polarity of these molecules, coupled with the absence of chromophores and fluorophores, poses significant challenges for their detection. In this study, a simple and highly sensitive analytical method was developed by coupling cold‐induced liquid‐liquid extraction (CI‐LLE) pretreatment with high‐performance liquid chromatography‐fluorescence detection, enabling the simultaneous determination of GLU, GLP, and its metabolite aminomethylphosphonic acid (they are denoted as GLP‐based compounds) in environmental water. CI‐LLE employs an acetonitrile/water mixture, which is frozen at ‐22°C to induce phase separation, resulting in an upper acetonitrile‐rich phase and a lower water‐rich phase, thereby achieving effective enrichment and purification of the target compounds. The GLP‐based compounds enriched in the aqueous phase were subsequently derivatized with 9‐fluoromethyl chloroformate to obtain fluorescent derivatives for detection. The parameters for CI‐LLE (treatment time, concentration of chelating agents, sample pH, and acetonitrile content) as well as derivatization conditions (including pH, reagent concentration, and reaction time) were systematically optimized. The developed method exhibited excellent sensitivity (with limits of detection in the range of 0.1–0.4 µg L −1 ), satisfactory recoveries (81.0%–105.2%), and repeatability (relative standard deviations
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Environmental & Municipal Engineering, Qingdao University of Technology, Qingdao, China.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Shandong Province
Zitieren
APA
Huang, C., Wang, L., Zhang, H., Tan, W., Wu, L., Wang, S., & Ma, J. (2026). Cold‐Induced Phase Separation Coupled With High‐Performance Liquid Chromatography‐Fluorescence Detection for Determination of Glyphosate, Aminomethylphosphonic Acid, and Glufosinate in Environmental Water. Journal of Separation Science, 49(3). https://doi.org/10.1002/jssc.70399
Vancouver
Huang C, Wang L, Zhang H, Tan W, Wu L, Wang S, et al. Cold‐Induced Phase Separation Coupled With High‐Performance Liquid Chromatography‐Fluorescence Detection for Determination of Glyphosate, Aminomethylphosphonic Acid, and Glufosinate in Environmental Water. Journal of Separation Science. 2026;49(3). doi:10.1002/jssc.70399
BibTeX
@article{Huang2026,
author = {Huang, Chaonan and Wang, Li and Zhang, Huiqing and Tan, Weiqiang and Wu, Lingxia and Wang, ShaSha and Ma, Jiping},
title = {Cold‐Induced Phase Separation Coupled With High‐Performance Liquid Chromatography‐Fluorescence Detection for Determination of Glyphosate, Aminomethylphosphonic Acid, and Glufosinate in Environmental Water},
journal = {Journal of Separation Science},
year = {2026},
volume = {49},
number = {3},
doi = {10.1002/jssc.70399}
}
EUVIMED