EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Enantioseparation of Mirabegron Using Cyclodextrin‐based Chiral Columns: High‐performance Liquid Chromatography and Molecular Modeling Study

Ali Mhammad, Gergely Dombi, Máté Dobó, Zoltán-István Szabó, Béla Fiser, Gergő Tóth

Journal of Separation Science · 2025

DOI: 10.1002/jssc.70132 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Separation Science, 2025. Verfasst von Ali Mhammad und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Chemistry, Semmelweis University, Budapest, Hungary. Hauptthemen laut MEDLINE: Acetanilides, Thiazoles, Cyclodextrins. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research, Development, and Innovation Office, Hungary, János Bolyai Research Scholarship of the Hungarian Academy of Sciences, National Research, Development, and Innovation Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A novel high‐performance liquid chromatography method for the enantioseparation of mirabegron ( R ‐mirabegron), a selective β‐3 adrenergic receptor agonist, using cyclodextrin (CD)‐based chiral stationary phases (CSPs) was developed. Seven different CSPs containing β‐, γ‐, hydroxypropyl‐β‐, sulfobutyl‐β‐, carboxymethyl‐β‐, permethyl‐β‐, and phenylcarbamate‐β‐cyclodextrin were evaluated under both polar organic and reversed‐phase conditions. Only the phenylcarbamate‐β‐cyclodextrin containing the Chiral CD‐Ph column displayed enantiorecognition. Optimization of conditions using a full factorial design led to the determination of the most suitable conditions: a mobile phase composition of 90:10:0.1 methanol:water:diethylamine, a flow rate of 0.8 mL/min, and a column temperature of 40°C with enantiomeric elution order, where the impurity S ‐mirabegron elutes first. Using the optimized conditions, enantioseparation with R s = 1.9 was achieved within 10 min. The developed method was validated according to current guidelines and successfully applied for the determination of S ‐mirabegron, as a chiral impurity in pharmaceutical formulations. The enantiorecognition mechanism was investigated by molecular docking and thermodynamic analysis. Using molecular modeling, the interactions between CDs and the analyte were analyzed at the molecular level, revealing that mirabegron interacts primarily with the phenylcarbamate groups on the outer surface of the structure. Enthalpy‐controlled enantioseparation was consistently observed across all eluent compositions, regardless of the conditions. The developed and validated method is highly suitable for routine determination of the enantiomeric purity of mirabegron, offering a reliable tool for regulatory compliance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AcetanilidesThiazolesCyclodextrinsChromatography, High Pressure LiquidStereoisomerismModels, MolecularMolecular Structure

Stichwörter der Autor:innen

Betmigachiral recognitionchiral separationcyclodextrinmirabegron

Substanzen

mirabegronAcetanilidesThiazolesCyclodextrins

Autor:innen und Institutionen

  • Department of Pharmaceutical Chemistry, Semmelweis University, Budapest, Hungary.
  • Center for Pharmacology and Drug Research & Development, Semmelweis University, Budapest, Hungary.
  • George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Targu Mures, Romania.
  • Sz-imfidum Ltd, Lunga, Romania.
  • Institute of Chemistry, University of Miskolc, Miskolc, Hungary.
  • Department of Biology and Chemistry, Ferenc Rákóczi II Transcarpathian Hungarian College of Higher Education, Transcarpathia, Ukraine.

Förderung

  • National Research, Development, and Innovation Office, Hungary
  • János Bolyai Research Scholarship of the Hungarian Academy of Sciences
  • National Research, Development, and Innovation Fund

Zitieren

APA

Mhammad, A., Dombi, G., Dobó, M., Szabó, Z. I., Fiser, B., & Tóth, G. (2025). Enantioseparation of Mirabegron Using Cyclodextrin‐based Chiral Columns: High‐performance Liquid Chromatography and Molecular Modeling Study. Journal of Separation Science. https://doi.org/10.1002/jssc.70132

Vancouver

Mhammad A, Dombi G, Dobó M, Szabó ZI, Fiser B, Tóth G. Enantioseparation of Mirabegron Using Cyclodextrin‐based Chiral Columns: High‐performance Liquid Chromatography and Molecular Modeling Study. Journal of Separation Science. 2025. doi:10.1002/jssc.70132

BibTeX
@article{Mhammad2025,
  author = {Mhammad, Ali and Dombi, Gergely and Dobó, Máté and Szabó, Zoltán-István and Fiser, Béla and Tóth, Gergő},
  title = {Enantioseparation of Mirabegron Using Cyclodextrin‐based Chiral Columns: High‐performance Liquid Chromatography and Molecular Modeling Study},
  journal = {Journal of Separation Science},
  year = {2025},
  doi = {10.1002/jssc.70132}
}
Kostenlos starten →