Fachartikel in der Zeitschrift Journal of Orthopaedic Research, online erschienen am 16.11.2026. Verfasst von Carolina S Haboba Nebel und 10 weiteren Autor:innen. Beteiligte Einrichtung: Rush University Medical Center, Chicago, Illinois, USA. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Prosthesis Failure. Die Arbeit nennt 18 Literaturangaben. Gefördert von: NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Unicondylar knee arthroplasty (UKA) utilization is expanding rapidly, and polyethylene wear remains a primary driver of long‐term failure in low‐conformity designs. This study quantitatively characterized the morphology and spatial distribution of wear scars in 95 surgically retrieved low‐conformity UKA tibial inserts to identify patient and implant factors that drive wear magnitude and location. The tibial liners were evenly distributed between males and females, 88.5% were medial, median time in situ was 7 years (range: 2–21.5 years), median age at implantation was 61.5 years (range: 35.1–77.5 years), and ten designs were represented. High‐resolution digital microscopy images analyzed through ImageJ were utilized to quantify wear scar area and wear scar location. Median wear scar area occupied around one‐third of the articular surface. Multivariable Generalized Linear Models confirmed that larger wear areas were independently predicted by younger age at implantation ( p ≤ 0.02) and longer time in situ ( p ≤ 0.04). Among high‐volume designs ( n > 15) in the medial side‐only cohort, historical conventional polyethylene showed significantly larger wear areas than highly cross‐linked polyethylene (53% vs. 30%; p = 0.004), and larger centroid shifts (15.9% vs. 10.6%; p = 0.01), indicating more decentralized loading. This retrieval study shows that polyethylene degradation is therefore multifactorial: younger age at implantation accelerates wear magnitude, while time in situ, articular design and material type dictate wear propagation and tracking stability. Younger patients undergoing medial UKA represent a high‐risk cohort; selecting modern implant designs with highly cross‐linked polyethylene and geometric profiles that minimize peripheral centroid shifts may reduce edge loading and improve long‐term survivorship.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeKnee ProsthesisProsthesis FailureHumansFemaleAgedMaleMiddle AgedAdultProsthesis DesignPolyethylene

Stichwörter der Autor:innen

polyethylene wearretrieval analysisunicondylar knee arthroplasty (UKA)wear scar locationwear scar magnitude

Substanzen

Polyethylene

Autor:innen und Institutionen

  • Rush University Medical Center, Chicago, Illinois, USA.

ORCID-Profile: Carolina S Haboba Nebel, Aditya S Yadav, Deborah J Hall, Hannah J Lundberg, Robin Pourzal

Förderung

  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Haboba Nebel, C. S., Potluri, A. S., Yadav, A. S., Debenedetti, A., Schulte, S., Wright, J. L., Hall, D. J., Bailey Terhune, E., Lundberg, H. J., Pourzal, R., & Valle, C. D. (2026). Wear Scar Morphology and Distribution in Retrieved Unicondylar Knee Arthroplasty Implants: Influence of Patient and Implant Factors. Journal of Orthopaedic Research, 44(11). https://doi.org/10.1002/jor.70317

Vancouver

Haboba Nebel CS, Potluri AS, Yadav AS, Debenedetti A, Schulte S, Wright JL, et al. Wear Scar Morphology and Distribution in Retrieved Unicondylar Knee Arthroplasty Implants: Influence of Patient and Implant Factors. Journal of Orthopaedic Research. 2026;44(11). doi:10.1002/jor.70317

BibTeX
@article{HabobaNebel2026,
  author = {Haboba Nebel, Carolina S and Potluri, Ajay S and Yadav, Aditya S and Debenedetti, Anne and Schulte, Spencer and Wright, Jennifer L and Hall, Deborah J and Bailey Terhune, E and Lundberg, Hannah J and Pourzal, Robin and Valle, Craig Della},
  title = {Wear Scar Morphology and Distribution in Retrieved Unicondylar Knee Arthroplasty Implants: Influence of Patient and Implant Factors},
  journal = {Journal of Orthopaedic Research},
  year = {2026},
  volume = {44},
  number = {11},
  doi = {10.1002/jor.70317}
}
Kostenlos starten →