EUVIMEDEUVIMED entdecken
Crossref

Finite Element Model of Patient‐Specific Flanged Acetabular Components Highlights Biomechanical Effects of Bone Density and Cortical Shell Thickness

Haena-Young Lee iD, Friedrich Boettner, Jason L Blevins, Jose A Rodriguez, Joseph D Lipman, Fernando J Quevedo González iD, Mathias P Bostrom, Timothy M Wright, Peter K Sculco

Journal of Orthopaedic Research · 2025

DOI: 10.1002/jor.26037 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Research, 2025. Verfasst von Haena-Young Lee und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomechanics, Hospital for Special Surgery, New York, New York, USA. Hauptthemen laut MEDLINE: Finite Element Analysis, Acetabulum, Bone Density, Hip Prosthesis. Die Arbeit nennt 26 Literaturangaben. Gefördert von: Research reported in this publication was supported by the Stavros Niarchos Complex Joint Reconstruction Center at the Hospital for Special Surgery..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Patient‐specific flanged acetabular components are utilized to treat failed total hip arthroplasties with severe acetabular defects. We previously developed and published a finite element model that investigated the impact of hip joint center lateralization on construct biomechanics during gait conditions. This model consisted of a patient‐specific implant designed to address a superior‐medial defect created in a standard pelvic geometry. This study aims to utilize the same model and examine how cortical shell thickness and ischial cancellous bone density affect the strain distribution in the bone and bone–implant micromotion. Using published studies and bone density analyses of patients who had undergone total hip arthroplasties with flanged acetabular components, we established a thickness range for the cortical shell (1.5, 1, and 0.75 mm) and two levels of ischial cancellous bone density (100% and 25%). We compared the resulting bone strains against the fatigue strength of the bone (0.3% strain) as a criterion for local bone failure and the bone–implant micromotion against the threshold associated with bone ingrowth (20 µm). A thinner pelvic cortical shell and lower ischial cancellous bone density increased areas of bone at risk of failure, particularly at the ischial screws (from 6% to 38%), and decreased areas compatible with bone ingrowth. These findings agree with our clinical knowledge that compromised ischial bone and inadequate ischial fixation negatively impact the survivorship of flanged acetabular components. This series establishes our modeling approach of a computational model that can be utilized to guide implant design to best treat unique acetabular defects.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Finite Element AnalysisAcetabulumBone DensityHip ProsthesisArthroplasty, Replacement, HipHumansBiomechanical PhenomenaCortical BoneMale

Stichwörter der Autor:innen

acetabular bone lossbiomechanicsfinite element modelinghiprevision total hip arthroplasty

Autor:innen und Institutionen

  • Department of Biomechanics, Hospital for Special Surgery, New York, New York, USA.
  • Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, New York, USA.

ORCID-Profile: Haena-Young Lee, Fernando J Quevedo González

Förderung

  • Research reported in this publication was supported by the Stavros Niarchos Complex Joint Reconstruction Center at the Hospital for Special Surgery.

Zitieren

APA

Lee, H. Y., Boettner, F., Blevins, J. L., Rodriguez, J. A., Lipman, J. D., Quevedo González, F. J., Bostrom, M. P., Wright, T. M., & Sculco, P. K. (2025). Finite Element Model of Patient‐Specific Flanged Acetabular Components Highlights Biomechanical Effects of Bone Density and Cortical Shell Thickness. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.26037

Vancouver

Lee HY, Boettner F, Blevins JL, Rodriguez JA, Lipman JD, Quevedo González FJ, et al. Finite Element Model of Patient‐Specific Flanged Acetabular Components Highlights Biomechanical Effects of Bone Density and Cortical Shell Thickness. Journal of Orthopaedic Research. 2025. doi:10.1002/jor.26037

BibTeX
@article{Lee2025,
  author = {Lee, Haena-Young and Boettner, Friedrich and Blevins, Jason L and Rodriguez, Jose A and Lipman, Joseph D and Quevedo González, Fernando J and Bostrom, Mathias P and Wright, Timothy M and Sculco, Peter K},
  title = {Finite Element Model of Patient‐Specific Flanged Acetabular Components Highlights Biomechanical Effects of Bone Density and Cortical Shell Thickness},
  journal = {Journal of Orthopaedic Research},
  year = {2025},
  doi = {10.1002/jor.26037}
}
Kostenlos starten →