Improved Discrimination of Mass Spectral Isomers Using the High‐Dimensional Consensus Mass Spectral Similarity Algorithm

Deborah F McGlynn iD, Nirina Rabe Andriamaharavo, Anthony J Kearsley iD

Journal of Mass Spectrometry · 2024-10 · 59 (10)

DOI: 10.1002/jms.5084 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Mass Spectrometry, online erschienen am 11.09.2024. Verfasst von Deborah F McGlynn und 2 weiteren Autor:innen. Beteiligte Einrichtung: Applied and Computational Mathematics Division, National Institute of Standards and Technology, Gaithersburg, Maryland, USA. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study employs a high‐dimensional consensus mass spectral (HDCMS) similarity scoring technique to discriminate isomers collected using an electron ionization mass spectrometer. The HDCMS method was previously introduced and applied to the discrimination of mass spectra of constitutional isomers, methamphetamine and phentermine, collected with direct analysis real‐time mass spectrometry (DART‐MS). The method formulates the problem of discriminating mass spectra in a mathematical Hilbert space and is hence called “high dimensional.” It requires replicate mass spectra to build a Gaussian model and evaluate the inner products between these functions. The resulting measurement variability is used as a signature by which to discriminate spectra. In this work, HDCMS is tested on electron impact ionization (EI) mass spectra of 7 terpene and terpene‐related (C 10 H 16 and C 10 H 14 ) isomers with experimental retention indices that differ by less than 30 and with traditional cosine similarity scores greater than 0.9, on a scale of 0 to 1, when compared with at least one other compound in the test set. Using identical instrument parameters, 15 replicate gas chromatography–electron ionization–mass spectrometry (GC‐EI‐MS) spectra of each isomer were collected and separated into distinct library and query sets. The HDCMS algorithm discriminated each isomer, indicating the method's potential. Because the method requires replicate measurements, observations from a simple heuristic study of the number of replicates required to discriminate these isomers is presented. The paper concludes with a discussion of compound discrimination using HDCMS and the benefits and drawbacks of applying the method to EI‐MS data.

Schlagwörter

Stichwörter der Autor:innen

compound discriminationhigh‐dimensional consensus mass spectraisomersmass spectral similaritymass spectrometryprobability distributions

Autor:innen und Institutionen

  • Applied and Computational Mathematics Division, National Institute of Standards and Technology, Gaithersburg, Maryland, USA.
  • Mass Spectrometry Data Center, National Institute of Standards and Technology, Gaithersburg, Maryland, USA.

ORCID-Profile: Deborah F McGlynn, Anthony J Kearsley

Zitieren

APA

McGlynn, D. F., Rabe Andriamaharavo, N., & Kearsley, A. J. (2024). Improved Discrimination of Mass Spectral Isomers Using the High‐Dimensional Consensus Mass Spectral Similarity Algorithm. Journal of Mass Spectrometry, 59(10). https://doi.org/10.1002/jms.5084

Vancouver

McGlynn DF, Rabe Andriamaharavo N, Kearsley AJ. Improved Discrimination of Mass Spectral Isomers Using the High‐Dimensional Consensus Mass Spectral Similarity Algorithm. Journal of Mass Spectrometry. 2024;59(10). doi:10.1002/jms.5084

BibTeX
@article{McGlynn2024,
  author = {McGlynn, Deborah F and Rabe Andriamaharavo, Nirina and Kearsley, Anthony J},
  title = {Improved Discrimination of Mass Spectral Isomers Using the High‐Dimensional Consensus Mass Spectral Similarity Algorithm},
  journal = {Journal of Mass Spectrometry},
  year = {2024},
  volume = {59},
  number = {10},
  doi = {10.1002/jms.5084}
}
Kostenlos starten →