Reduction of metal artefacts from bilateral hip prostheses during lower extremity computed tomography angiography: an experimental phantom study
Journal of Medical Radiation Sciences · 2024
DOI: 10.1002/jmrs.797 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Radiation Sciences, 2024. Verfasst von Omarah N Abdalqader und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging, Faculty of Health Professions, Al-Quds University, Jerusalem, Palestine. Hauptthemen laut MEDLINE: Phantoms, Imaging, Artifacts, Hip Prosthesis, Computed Tomography Angiography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Introduction
Image quality reduction due to metallic artefacts is a significant challenge during vascular computed tomography (CT) imaging of the lower extremities in patients with hip prostheses. This study aims to analyse various reconstruction algorithms' ability to reduce metal artefacts due to two types of hip prostheses during lower extremity CT angiography examinations.
Methods
A pelvis phantom was fabricated with the insertion of a tube filled with contrast media to simulate the femoral artery, and the phantom was then CT scanned with and without hip prostheses. Multimodal images were acquired using different kilovoltage peak (kVp) settings and reconstructed with different algorithms, such as filtered back projection (FBP), iterative reconstruction (iDose 4 ), iterative model‐based reconstruction (IMR) and orthopaedic metal artefact reduction (O‐MAR). Image quality was assessed based on image noise, signal‐to‐noise ratio (SNR) and Hounsfield unit (HU) deviation.
Results
The IMR approach significantly improved image quality compared to iDose 4 and FBP. For the vascular region, O‐MAR improves SNR by 5 ± 1, 23 ± 5 and 42 ± 9 for FBP, iDose 4 and IMR respectively, and improves HU precision towards the baseline values by 49% and 83% for FBP and IMR, respectively. The noise reduction was 71% and 89% for FBP and IMR, and 57% for iDose 4 . O‐MAR greatly enhances SNR corrections among the most severe artefacts, with 29 ± 1 and 43 ± 4 for FBP and IMR, compared to iDose 4 by 37 ± 7.
Conclusion
IMR combined with O‐MAR could improve the CT angiography of the lower extremities of patients with a hip prosthesis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medical Imaging, Faculty of Health Professions, Al-Quds University, Jerusalem, Palestine.
- Department of Medical Imaging, Faculty of Allied Medical Sciences, Arab American University, Jenin, Palestine.
- Department of Mathematics, Khalifa University, Abu Dhabi, UAE.
- Medical Diagnostic Imaging Department, College of Health Sciences, University of Sharjah, Sharjah, UAE.
- Department of Radiology, Turkish Friendship Hospital, Gaza Strip, Palestine.
ORCID-Profile: Mohammad Aljamal, Mohamed Abuzaid
Zitieren
APA
Abdalqader, O. N., Hjouj, M., Aljamal, M., Hjouj, F., Abuzaid, M., & Mousa, M. (2024). Reduction of metal artefacts from bilateral hip prostheses during lower extremity computed tomography angiography: an experimental phantom study. Journal of Medical Radiation Sciences. https://doi.org/10.1002/jmrs.797
Vancouver
Abdalqader ON, Hjouj M, Aljamal M, Hjouj F, Abuzaid M, Mousa M. Reduction of metal artefacts from bilateral hip prostheses during lower extremity computed tomography angiography: an experimental phantom study. Journal of Medical Radiation Sciences. 2024. doi:10.1002/jmrs.797
BibTeX
@article{Abdalqader2024,
author = {Abdalqader, Omarah N and Hjouj, Mohammad and Aljamal, Mohammad and Hjouj, Fawaz and Abuzaid, Mohamed and Mousa, Mahmoud},
title = {Reduction of metal artefacts from bilateral hip prostheses during lower extremity computed tomography angiography: an experimental phantom study},
journal = {Journal of Medical Radiation Sciences},
year = {2024},
doi = {10.1002/jmrs.797}
}
EUVIMED