Phantom study of a self-shielded X-ray bone age assessment instrument against scattered radiation in children
Pediatric Radiology · 2024
DOI: 10.1007/s00247-024-05897-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pediatric Radiology, 2024. Verfasst von Xinhong Wang und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China. Hauptthemen laut MEDLINE: Radiation Protection. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 8 Literaturangaben. Gefördert von: the National Key Research and Development Program of China, Medical Health Science and Technology Project of Zhejiang Provincial Health Commission.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
Hand-wrist radiography is the most common and accurate method for evaluating children's bone age. To reduce the scattered radiation of radiosensitive organs in bone age assessment, we designed a small X-ray instrument with radioprotection function by adding metal enclosure for X-ray shielding. We used a phantom operator to compare the scattered radiation doses received by sensitive organs under three different protection scenarios (proposed instrument, radiation personal protective equipment, no protection). The proposed instrument showed greater reduction in the mean dose of a single exposure compared with radiation personal protective equipment especially on the left side which was proximal to the X-ray machine (≥80.0% in eye and thyroid, ≥99.9% in breast and gonad). The proposed instrument provides a new pathway towards more convenient and efficient radioprotection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
- Department of Radiology, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Taizhou, China.
- Hangzhou Mednova Medical Technologies Co., Ltd, Hangzhou, China.
- Department of Medical Imaging, Army 75 Group Military Hospital, Dali, China.
- Department of Critical Care Medicine, Shanghai East Hospital, Tongji University School of Medicine, 150 JiMo Road, Shanghai, China.
- S.M.U. Medical Equipment Test Co., Ltd, Guangzhou, China.
ORCID-Profile: Haipeng Liu
Förderung
- the National Key Research and Development Program of China
- Medical Health Science and Technology Project of Zhejiang Provincial Health Commission
Zitieren
APA
Wang, X., Xu, M., Zhu, H., Ma, L., Chen, C., Jiang, Q., Wu, W., Hu, D., Zhou, W., Chen, R., Gao, L., Yu, X., Wang, L., Cai, X., Liu, H., & Xia, L. (2024). Phantom study of a self-shielded X-ray bone age assessment instrument against scattered radiation in children. Pediatric Radiology. https://doi.org/10.1007/s00247-024-05897-6
Vancouver
Wang X, Xu M, Zhu H, Ma L, Chen C, Jiang Q, et al. Phantom study of a self-shielded X-ray bone age assessment instrument against scattered radiation in children. Pediatric Radiology. 2024. doi:10.1007/s00247-024-05897-6
BibTeX
@article{Wang2024,
author = {Wang, Xinhong and Xu, Mengxi and Zhu, Huayong and Ma, Linlin and Chen, Cong and Jiang, Qing and Wu, Weihong and Hu, Daoxi and Zhou, Wei and Chen, Rongmin and Gao, Lili and Yu, Xiaoli and Wang, Lijian and Cai, Xiaoxiao and Liu, Haipeng and Xia, Ling},
title = {Phantom study of a self-shielded X-ray bone age assessment instrument against scattered radiation in children},
journal = {Pediatric Radiology},
year = {2024},
doi = {10.1007/s00247-024-05897-6}
}
EUVIMED