EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of 1024‐Matrix Size on Perforating Artery Visualisation in Cerebral Computed Tomography Angiography Using a 64‐Slice CT Scanner

Hokuto Nagumo iD, Yuki Nagata, Mayumi Maruko, Jun Sakai, Yusuke Fujiwara, Joma Oikawa iD

Journal of Medical Radiation Sciences · 2026

DOI: 10.1002/jmrs.70055 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medical Radiation Sciences, 2026. Verfasst von Hokuto Nagumo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Sapporo Shuyukai Hospital, Sapporo, Japan. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Cerebral Angiography, Cerebral Arteries, Tomography Scanners, X-Ray Computed. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Healthcare University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Computed tomography angiography (CTA) is essential for preoperative evaluation of intracranial vessels; however, the visualisation of small perforating arteries remains challenging with conventional systems. This study investigated whether increasing the reconstruction matrix size from 512 to 1024 pixels improves the visualisation of perforating arteries in cerebral CTA using a standard 64‐slice computed tomography (CT) scanner.

Methods

The study comprised phantom and clinical components. Physical image properties were assessed through Task Transfer Function (TTF) and Noise Power Spectrum (NPS) analyses. In the clinical phase, 41 patients underwent cerebral CTA with both 512‐ and 1024‐matrix reconstructions. Quantitative analysis was performed to determine the peak CT values of the anterior choroidal artery and standard deviation in the basal cistern. Two independent observers (CT radiographers) evaluated the visualisation of anterior choroidal and posterior thalamoperforating arteries using a 5‐point scale.

Results

Physical metrics showed minimal differences between matrix sizes, with 5% TTF values of 0.862 and 0.867 cycles/mm for 512 and 1024 pixels, respectively. The anterior choroidal artery exhibited higher peak CT values with 1024 pixels (139.31 ± 27.02 HU vs. 136.85 ± 26.69 HU, p < 0.001). The qualitative assessment revealed significant improvements in vessel visualisation with 1024 pixels, particularly for the posterior thalamoperforating artery, where high‐quality visualisation increased from 17.07% to 39.03%.

Conclusions

Although increasing the matrix size from 512 to 1024 pixels did not significantly affect the physical image quality metrics, it enhanced the visual detection of small perforating arteries through enhanced sampling density. This optimization technique offers a practical approach for enhancing preoperative vessel evaluation using existing CT technology without requiring specialised equipment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computed Tomography AngiographyCerebral AngiographyCerebral ArteriesTomography Scanners, X-Ray ComputedHumansPhantoms, ImagingImage Processing, Computer-Assisted

Autor:innen und Institutionen

  • Department of Radiology, Sapporo Shuyukai Hospital, Sapporo, Japan.
  • Department of Neurosurgery, Sapporo Shuyukai Hospital, Sapporo, Japan.
  • Department of Radiological Technology, Japan Healthcare University, Sapporo, Japan.

ORCID-Profile: Hokuto Nagumo, Joma Oikawa

Förderung

  • Japan Healthcare University

Zitieren

APA

Nagumo, H., Nagata, Y., Maruko, M., Sakai, J., Fujiwara, Y., & Oikawa, J. (2026). Impact of 1024‐Matrix Size on Perforating Artery Visualisation in Cerebral Computed Tomography Angiography Using a 64‐Slice CT Scanner. Journal of Medical Radiation Sciences. https://doi.org/10.1002/jmrs.70055

Vancouver

Nagumo H, Nagata Y, Maruko M, Sakai J, Fujiwara Y, Oikawa J. Impact of 1024‐Matrix Size on Perforating Artery Visualisation in Cerebral Computed Tomography Angiography Using a 64‐Slice CT Scanner. Journal of Medical Radiation Sciences. 2026. doi:10.1002/jmrs.70055

BibTeX
@article{Nagumo2026,
  author = {Nagumo, Hokuto and Nagata, Yuki and Maruko, Mayumi and Sakai, Jun and Fujiwara, Yusuke and Oikawa, Joma},
  title = {Impact of 1024‐Matrix Size on Perforating Artery Visualisation in Cerebral Computed Tomography Angiography Using a 64‐Slice CT Scanner},
  journal = {Journal of Medical Radiation Sciences},
  year = {2026},
  doi = {10.1002/jmrs.70055}
}
Kostenlos starten →