An Analysis of Radiographers' False Preliminary Image Evaluation Comments in One New Zealand District
Journal of Medical Radiation Sciences · 2025
DOI: 10.1002/jmrs.70054 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Radiation Sciences, 2025. Verfasst von Kim Lewis und 3 weiteren Autor:innen. Beteiligte Einrichtung: Radiology Department, Te Whatu Ora Taranaki, New Plymouth, New Zealand. Hauptthemen laut MEDLINE: Radiography, Diagnostic Errors. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NZIMRT.
Abstract (Originalsprache)
Introduction
Preliminary image evaluation (PIE) is an abnormality detection system that enables radiographers to assist emergency department (ED) clinicians in their treatment decisions by minimising radiographic interpretation errors. For a PIE to be successful, radiographers need to provide accurate comments on images. Given the limited number of studies that evaluate radiographers' false PIE comments, the aim of this study was to determine common false negative (FN) and false positive (FP) comments in one district in New Zealand (NZ).
Methods
Six months of PIE comments performed in the Taranaki district in NZ were collected and scored into four categories: true positive, true negative, FP or FN. The FN and FP comments were then evaluated to determine common errors and compared with international research.
Results
A total of 844 PIE comments were collected, with 21 (2.5%) scored as FN, and 27 (3.2%) scored as FP. The common FN themes included subtle or avulsion fractures, predominantly in fingers, hands, and wrists. The common FP themes were normal variants in the foot and ankle that were mistaken for fractures.
Conclusion
Several recommendations are made from this study to help improve radiographer PIE accuracy. These include the addition of an unsure or equivocal category when scoring PIE comments to account for PIE comments with ambiguous language. Other recommendations include ongoing targeted training of common errors and a higher resolution monitor (generally used for image reporting by radiologists) for radiographers when performing PIE.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Radiology Department, Te Whatu Ora Taranaki, New Plymouth, New Zealand.
- Department of Anatomy and Medical Imaging, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand.
ORCID-Profile: Kim Lewis, Sibusiso Mdletshe, Tracey Pieterse
Förderung
- NZIMRT
Zitieren
APA
Lewis, K., Mdletshe, S., Doubleday, A., & Pieterse, T. (2025). An Analysis of Radiographers' False Preliminary Image Evaluation Comments in One New Zealand District. Journal of Medical Radiation Sciences. https://doi.org/10.1002/jmrs.70054
Vancouver
Lewis K, Mdletshe S, Doubleday A, Pieterse T. An Analysis of Radiographers' False Preliminary Image Evaluation Comments in One New Zealand District. Journal of Medical Radiation Sciences. 2025. doi:10.1002/jmrs.70054
BibTeX
@article{Lewis2025,
author = {Lewis, Kim and Mdletshe, Sibusiso and Doubleday, Andrea and Pieterse, Tracey},
title = {An Analysis of Radiographers' False Preliminary Image Evaluation Comments in One New Zealand District},
journal = {Journal of Medical Radiation Sciences},
year = {2025},
doi = {10.1002/jmrs.70054}
}
EUVIMED