Fachartikel in der Zeitschrift Journal of Medical Radiation Sciences, 2024. Verfasst von Jermayne Takapautolo und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging, Logan Hospital, Meadowbrook, Queensland, Australia. Hauptthemen laut MEDLINE: Diagnostic Errors. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Diagnostic errors in the emergency departments can have major implications on patient outcomes. Preliminary Image Evaluation (PIE) is a brief comment written by a radiographer describing an acute or traumatic pathology on a radiograph and can be used to complement referrer's image interpretation in the absence of the radiologist report. Currently, no studies exist that focus their analysis on false‐positive (FP) errors in PIE. The purpose of this study was to investigate the regions of the body that cause the most FP errors and recognise other areas in image interpretation that may need additional attention.
Methods
A longitudinal retrospective clinical audit was conducted to determine the accuracy of radiographer PIE's over 5 years from January 2016 to December 2020. PIE's were compared to the radiologist report to assess for diagnostic accuracy. FP and unsure errors were further categorised by anatomical region and age.
Results
Over this period, a sample size of 11,090 PIE audits were included in the study demonstrating an overall PIE accuracy of 87.7%. Foot, ankle and chest regions caused the most FP errors, while ankle, shoulder and elbow caused the most unsure cases. 76% of the unsure cases were negative for any pathology when compared to the radiologist report. The paediatric population accounted for 21.3% of FP cases and 33.6% of unsure cases.
Conclusion
Findings in this study should be used to tailor education specific to radiographer image interpretation. Improving radiography image interpretation skills can assist in improving referrer diagnostic accuracy, thus improving patient outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Imaging, Logan Hospital, Meadowbrook, Queensland, Australia.
- School of Clinical Sciences, Queensland University of Technology, Brisbane, Australia.
ORCID-Profile: Jermayne Takapautolo, Deborah Starkey
Zitieren
APA
Takapautolo, J., Neep, M., & Starkey, D. (2024). Analysing false‐positive errors when Australian radiographers use preliminary image evaluation. Journal of Medical Radiation Sciences. https://doi.org/10.1002/jmrs.809
Vancouver
Takapautolo J, Neep M, Starkey D. Analysing false‐positive errors when Australian radiographers use preliminary image evaluation. Journal of Medical Radiation Sciences. 2024. doi:10.1002/jmrs.809
BibTeX
@article{Takapautolo2024,
author = {Takapautolo, Jermayne and Neep, Michael and Starkey, Deborah},
title = {Analysing false‐positive errors when Australian radiographers use preliminary image evaluation},
journal = {Journal of Medical Radiation Sciences},
year = {2024},
doi = {10.1002/jmrs.809}
}
EUVIMED