Fachartikel in der Zeitschrift Journal of Medical Radiation Sciences, 2024. Verfasst von Jermayne Takapautolo und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging, Logan Hospital, Meadowbrook, Queensland, Australia. Hauptthemen laut MEDLINE: Diagnostic Errors. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Diagnostic errors in the emergency departments can have major implications on patient outcomes. Preliminary Image Evaluation (PIE) is a brief comment written by a radiographer describing an acute or traumatic pathology on a radiograph and can be used to complement referrer's image interpretation in the absence of the radiologist report. Currently, no studies exist that focus their analysis on false‐positive (FP) errors in PIE. The purpose of this study was to investigate the regions of the body that cause the most FP errors and recognise other areas in image interpretation that may need additional attention.

Methods

A longitudinal retrospective clinical audit was conducted to determine the accuracy of radiographer PIE's over 5 years from January 2016 to December 2020. PIE's were compared to the radiologist report to assess for diagnostic accuracy. FP and unsure errors were further categorised by anatomical region and age.

Results

Over this period, a sample size of 11,090 PIE audits were included in the study demonstrating an overall PIE accuracy of 87.7%. Foot, ankle and chest regions caused the most FP errors, while ankle, shoulder and elbow caused the most unsure cases. 76% of the unsure cases were negative for any pathology when compared to the radiologist report. The paediatric population accounted for 21.3% of FP cases and 33.6% of unsure cases.

Conclusion

Findings in this study should be used to tailor education specific to radiographer image interpretation. Improving radiography image interpretation skills can assist in improving referrer diagnostic accuracy, thus improving patient outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diagnostic ErrorsHumansFalse Positive ReactionsAustraliaRetrospective StudiesChildAdultAdolescentMaleFemaleChild, PreschoolRadiographyRadiologistsMiddle Aged

Stichwörter der Autor:innen

Clinical auditX‐raydiagnostic errorsemergency departmentradiographer

Autor:innen und Institutionen

  • Department of Medical Imaging, Logan Hospital, Meadowbrook, Queensland, Australia.
  • School of Clinical Sciences, Queensland University of Technology, Brisbane, Australia.

ORCID-Profile: Jermayne Takapautolo, Deborah Starkey

Zitieren

APA

Takapautolo, J., Neep, M., & Starkey, D. (2024). Analysing false‐positive errors when Australian radiographers use preliminary image evaluation. Journal of Medical Radiation Sciences. https://doi.org/10.1002/jmrs.809

Vancouver

Takapautolo J, Neep M, Starkey D. Analysing false‐positive errors when Australian radiographers use preliminary image evaluation. Journal of Medical Radiation Sciences. 2024. doi:10.1002/jmrs.809

BibTeX
@article{Takapautolo2024,
  author = {Takapautolo, Jermayne and Neep, Michael and Starkey, Deborah},
  title = {Analysing false‐positive errors when Australian radiographers use preliminary image evaluation},
  journal = {Journal of Medical Radiation Sciences},
  year = {2024},
  doi = {10.1002/jmrs.809}
}
Kostenlos starten →