EUVIMEDEUVIMED entdecken
Crossref

Direct Observation of Dynamic Cerebrospinal Fluid Flow Velocity in the Lumbar Spinal Canal During Deep Respiration Using a Modified Time‐Spatial Labeling Inversion Pulse Technique

Ryo Yamakuni iD, Shinya Seino, Takeyasu Kakamu iD, Hironobu Ishikawa iD, Hirofumi Sekino iD, Shiro Ishii iD, Hiroshi Kobayashi iD, Takuya Nikaido iD, Kazuyuki Watanabe iD, Koji Otani iD, Kenji Fukushima iD, Yoshihiro Matsumoto und 1 weitere

Journal of Magnetic Resonance Imaging · 2026-12 · 64 (6) · 1692-1708

DOI: 10.1002/jmri.70461 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, online erschienen am 15.07.2026. Verfasst von Ryo Yamakuni und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Nuclear Medicine, Fukushima Medical University School of Medicine, Fukushima, Japan. Hauptthemen laut MEDLINE: Respiration, Cerebrospinal Fluid, Magnetic Resonance Imaging, Lumbar Vertebrae. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

A previous single‐case study has demonstrated that a modified time‐spatial labeling inversion pulse (Time‐SLIP) technique, specifically Deep Abdominal Breathing‐induced CSF Flow Imaging with Time‐SLIP (DAB Time‐SLIP), successfully visualized dynamic cerebrospinal fluid (CSF) flow during deep breathing with superior contrast compared to conventional Time‐SLIP. However, it is unclear whether this occurs consistently across healthy individuals.

Purpose

To investigate CSF flow dynamics during deep breathing in healthy volunteers with the DAB Time‐SLIP. Study Type Prospective. Population 10 healthy participants (7 men; mean age, 29.5 years). Field Strength/Sequence 1.5‐Tesla, Time‐SLIP. Assessment Midsagittal Time‐SLIP imaging was performed using a 9 s repetition interval. A labeling pulse was applied at four vertebral levels (Th11–L1–L3–L5 or Th12–L2–L4–S1), and images were acquired after a 2 s delay. Separate imaging sessions were conducted during shallow breathing and during a structured 8 s deep abdominal breathing cycle. During deep‐abdominal‐breathing, an intentional phase shift between the 9 s imaging interval and the 8 s respiratory cycle enabled visualization of CSF movement across the entire cycle within 72 s. This protocol for CSF dynamics during deep‐breathing was designated as DAB Time‐SLIP. Images acquired under these two breathing conditions were compared with the reference label images obtained during breath‐holding, and CSF flow velocity and displacement range were quantified based on the resulting positional changes. Statistical Tests Wilcoxon signed‐rank test and simple linear regression analysis. A p < 0.05 was considered significant.

Results

Cranial flow occurred during inhalation, whereas caudal flow was observed during exhalation. Both the magnitude and the displacement range of CSF flow velocity and CSF movement of range progressively decreased toward the caudal direction (rS = −0.9479). Compared with free breathing, the range of CSF movement using DAB Time‐SLIP was significantly greater. Data Conclusion DAB Time‐SLIP demonstrated cranial CSF flow during deep inspiration and caudal CSF flow during deep expiration. Level of Evidence 1. Technical Efficacy Stage 1.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RespirationCerebrospinal FluidMagnetic Resonance ImagingLumbar VertebraeHumansMaleAdultFemaleProspective StudiesHealthy VolunteersImage Processing, Computer-AssistedYoung Adult

Stichwörter der Autor:innen

cerebrospinal fluiddeep respirationneurofluidtime‐spatial labeling inversion pulsevertebral venous system

Autor:innen und Institutionen

  • Department of Radiology and Nuclear Medicine, Fukushima Medical University School of Medicine, Fukushima, Japan.
  • Department of Radiology, Fukushima Medical University Hospital, Fukushima, Japan.
  • Department of Hygiene and Preventive Medicine, Fukushima Medical University School of Medicine, Fukushima, Japan.
  • Department of Orthopedic Surgery, Fukushima Medical University School of Medicine, Fukushima, Japan.

ORCID-Profile: Ryo Yamakuni, Takeyasu Kakamu, Hironobu Ishikawa, Hirofumi Sekino, Shiro Ishii, Hiroshi Kobayashi, Takuya Nikaido, Kazuyuki Watanabe, Koji Otani, Kenji Fukushima

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Yamakuni, R., Seino, S., Kakamu, T., Ishikawa, H., Sekino, H., Ishii, S., Kobayashi, H., Nikaido, T., Watanabe, K., Otani, K., Fukushima, K., Matsumoto, Y., & Ito, H. (2026). Direct Observation of Dynamic Cerebrospinal Fluid Flow Velocity in the Lumbar Spinal Canal During Deep Respiration Using a Modified Time‐Spatial Labeling Inversion Pulse Technique. Journal of Magnetic Resonance Imaging, 64(6), 1692-1708. https://doi.org/10.1002/jmri.70461

Vancouver

Yamakuni R, Seino S, Kakamu T, Ishikawa H, Sekino H, Ishii S, et al. Direct Observation of Dynamic Cerebrospinal Fluid Flow Velocity in the Lumbar Spinal Canal During Deep Respiration Using a Modified Time‐Spatial Labeling Inversion Pulse Technique. Journal of Magnetic Resonance Imaging. 2026;64(6):1692-1708. doi:10.1002/jmri.70461

BibTeX
@article{Yamakuni2026,
  author = {Yamakuni, Ryo and Seino, Shinya and Kakamu, Takeyasu and Ishikawa, Hironobu and Sekino, Hirofumi and Ishii, Shiro and Kobayashi, Hiroshi and Nikaido, Takuya and Watanabe, Kazuyuki and Otani, Koji and Fukushima, Kenji and Matsumoto, Yoshihiro and Ito, Hiroshi},
  title = {Direct Observation of Dynamic Cerebrospinal Fluid Flow Velocity in the Lumbar Spinal Canal During Deep Respiration Using a Modified Time‐Spatial Labeling Inversion Pulse Technique},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2026},
  volume = {64},
  number = {6},
  pages = {1692--1708},
  doi = {10.1002/jmri.70461}
}
Kostenlos starten →