Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 17.05.2026. Verfasst von Pontus Söderström und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Applied Physics and Electronics, Umeå University, Umeå, Sweden. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Cerebrospinal Fluid, Brain. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hjärt-Lungfonden, Vetenskapsrådet, Stiftelsen för Strategisk Forskning.
Abstract (Originalsprache)
Purpose
Cerebrospinal fluid (CSF) flow oscillations have emerged as a potentially important marker related to brain clearance, but their acquisition often relies on specialized imaging MRI sequences. The purpose of this work was to enable quantitative assessment of CSF flow associated with cardiac, respiratory, and low‐frequency cycles using widely available functional magnetic resonance imaging (fMRI) acquisitions.
Methods
A method was developed to translate fMRI‐derived CSF inflow signals into quantitative flow rates. This approach modeled the spin‐history of an oscillating ensemble of molecules. Validation was performed using phantom experiments with cardiac‐, respiratory‐, and low‐frequency‐like oscillatory flow. The method was further applied to resting‐state data from 48 older adults (68–82 years, 19 women) to characterize CSF flow at the foramen magnum.
Results
Phantom experiments demonstrated excellent correlations between estimated and true velocities for cardiac‐ and respiratory‐like frequencies ( r = 0.94 and 0.97, respectively) and moderate correlation for the low‐frequency‐like oscillation ( r = 0.58). In the population cohort, median CSF stroke volumes were 0.77 [0.57, 1.09] mL for the cardiac cycle, 0.38 [0.26, 0.88] mL for the respiratory cycle, and 0.26 [0.14, 0.39] mL for the low‐frequency cycle.
Conclusion
The proposed spin‐history modeling method enabled quantitative estimation of CSF flow components using a conventional fMRI dataset and showed that the cardiac cycle dominates CSF motion at the foramen magnum.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Applied Physics and Electronics, Umeå University, Umeå, Sweden.
- Department of Diagnostics and Intervention, Biomedical Engineering and Radiation Physics, Umeå University, Umeå, Sweden.
- Umeå Center for Functional Brain Imaging (UFBI), Umeå University, Umeå, Sweden.
- Department of Clinical Science, Neurosciences, Umeå University, Umeå, Sweden.
ORCID-Profile: Pontus Söderström
Förderung
- Hjärt-Lungfonden
- Vetenskapsrådet
- Stiftelsen för Strategisk Forskning
Zitieren
APA
Söderström, P., Björnfot, C., Andersson, B. M., Malm, J., Eklund, A., & Wåhlin, A. (2026). Quantifying Cardiac, Respiratory, and Low Frequency Components of CSF Motion From fMRI Inflow Effects. Magnetic Resonance in Medicine, 96(4), 1916-1928. https://doi.org/10.1002/mrm.70438
Vancouver
Söderström P, Björnfot C, Andersson BM, Malm J, Eklund A, Wåhlin A. Quantifying Cardiac, Respiratory, and Low Frequency Components of CSF Motion From fMRI Inflow Effects. Magnetic Resonance in Medicine. 2026;96(4):1916-1928. doi:10.1002/mrm.70438
BibTeX
@article{Sderstrm2026,
author = {Söderström, Pontus and Björnfot, Cecilia and Andersson, Britt M and Malm, Jan and Eklund, Anders and Wåhlin, Anders},
title = {Quantifying Cardiac, Respiratory, and Low Frequency Components of CSF Motion From fMRI Inflow Effects},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {4},
pages = {1916--1928},
doi = {10.1002/mrm.70438}
}
EUVIMED