Zero Time‐to‐Echo Imaging of the Hand and Wrist in Rheumatoid Arthritis Patients
Journal of Magnetic Resonance Imaging · 2026
DOI: 10.1002/jmri.70420 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2026. Verfasst von Jun Tsukamoto und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Occupational and Environmental Health, Kitakyushu, Fukuoka, Japan. Hauptthemen laut MEDLINE: Arthritis, Rheumatoid, Magnetic Resonance Imaging, Hand, Wrist. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Zero time‐to‐echo (ZTE) imaging allows for signal acquisition from tissues with extremely short T2* relaxation times, enabling the generation of computed tomography (CT)‐like images through gray‐scale inversion.
Purpose
To assess the usefulness of adding ZTE imaging to conventional MRI for the detection of hand and wrist bone erosions in rheumatoid arthritis (RA) patients, using CT as the reference method. Study Type Prospective. Subjects Fifteen patients with RA (4 male and 11 female; mean age, 61.8 ± 15.5 years) participated in this study. Field Strength/Sequence 3‐T, T1‐weighted image (fast spin echo), T2‐weighted image (fast spin echo), ZTE imaging (gradient echo). Assessment Three radiologists independently evaluated bone erosions on plain radiography, conventional MRI, and ZTE imaging using a four‐point scale (0 = normal; 1 = discrete erosion; 2 ≤ 50% of joint surface involvement; 3 ≥ 50%). Bone erosion was defined as a sharply delineated juxta‐articular lesion with a cortical defect. A total of 25 anatomical sites per hand and wrist were assessed, including the distal radius and ulna, eight carpal bones, metacarpal bases, and proximal and distal aspects of the metacarpophalangeal joints. CT was interpreted by a musculoskeletal radiologist and served as the reference standard. Statistical Tests Diagnostic performance (sensitivity and specificity) was compared with the McNemar test, and interobserver variability was assessed using Fleiss κ statistics. p values less than 0.01 were considered significant.
Results
The sensitivity and specificity of plain radiography, conventional MRI, and ZTE were 40.6/98.9%, 72.6/94.6%, and 95.9/97.6%, respectively. Interobserver agreement on bone erosion assessment was excellent for ZTE imaging ( κ value of 0.822) but fair for plain radiography ( κ value of 0.427) and good for conventional MRI ( κ value of 0.711). Data Conclusions ZTE imaging can provide reliable bone erosion assessment in RA patients. Level of Evidence 2. Technical Efficacy Stage 2.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, University of Occupational and Environmental Health, Kitakyushu, Fukuoka, Japan.
- Department of Radiological Science, Faculty of Health Sciences, Junshin Gakuen University, Fukuoka, Japan.
- The First Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Fukuoka, Japan.
ORCID-Profile: Jun Tsukamoto, Atsushi Nagayasu, Yasuyuki Todoroki, Shingo Nakayamada, Yoshiya Tanaka, Takatoshi Aoki
Zitieren
APA
Tsukamoto, J., Fujisaki, A., Hayashida, Y., Murakami, S., Nagayasu, A., Todoroki, Y., Nakayamada, S., Tanaka, Y., & Aoki, T. (2026). Zero Time‐to‐Echo Imaging of the Hand and Wrist in Rheumatoid Arthritis Patients. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.70420
Vancouver
Tsukamoto J, Fujisaki A, Hayashida Y, Murakami S, Nagayasu A, Todoroki Y, et al. Zero Time‐to‐Echo Imaging of the Hand and Wrist in Rheumatoid Arthritis Patients. Journal of Magnetic Resonance Imaging. 2026. doi:10.1002/jmri.70420
BibTeX
@article{Tsukamoto2026,
author = {Tsukamoto, Jun and Fujisaki, Akitaka and Hayashida, Yoshiko and Murakami, Seiichi and Nagayasu, Atsushi and Todoroki, Yasuyuki and Nakayamada, Shingo and Tanaka, Yoshiya and Aoki, Takatoshi},
title = {Zero Time‐to‐Echo Imaging of the Hand and Wrist in Rheumatoid Arthritis Patients},
journal = {Journal of Magnetic Resonance Imaging},
year = {2026},
doi = {10.1002/jmri.70420}
}
EUVIMED