Optimal Selection of the Effective Echo Time ( TE eff ) for T2 ‐Weighted Fast‐Spin‐Echo MRI of the Prostate at 3.0 T: Effect on Lesion Conspicuity
Journal of Magnetic Resonance Imaging · 2026-09 · 64 (3) · 616-628
DOI: 10.1002/jmri.70351 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, online erschienen am 23.04.2026. Verfasst von Dahan Kim und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Prostate, Magnetic Resonance Imaging. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCRR NIH HHS, NIBIB NIH HHS, NIH HHS.
Abstract (Originalsprache)
Background
Clinical T 2 ‐weighted (T2W) MRI of prostate cancer (PCa) usually implements a 2D fast‐spin‐echo (FSE) sequence, but understanding the echo‐time‐dependent contrast behavior is not straightforward due to the complicated FSE signal evolution. Consequently, consensus‐based recommendations on the optimal effective echo time (TE eff ) to maximize contrast are lacking.
Purpose
To investigate the effect of TE eff on PCa lesion contrast in prostate T2W MRI. Study Type Phantom and in vivo prospective study. Subjects A standard MRI phantom and 53 prostate cancer patients (29 for image evaluation and 24 for quantitative lesion analysis). Field Strength and Sequence Multi‐slice T2W FSE sequence at 3 T acquired at multiple TE eff values. Assessment Three readers (13, 25, and 27 years' experience) evaluated TE eff = 100 ms versus 150 ms on diagnostic quality and reader preference. The effective T 2 relaxation rates ( T 2,eff ) were measured using FSE sequences in the phantom and used to predict the optimal TE eff maximizing T2W contrasts. From multi‐TE eff scans of subjects with suspected PCa, T 2,eff values of PCa lesions and healthy tissue were measured and used to calculate the optimal TE eff maximizing the lesion contrast. In vivo contrast metrics were measured as a function of TE eff . Statistical Tests Wilcoxon test of reader scores, with p < 0.05 defining statistical significance.
Results
No statistically significant difference was found in diagnostic quality between TE eff = 150 ms and 100 ms images, but all three readers significantly favored TE eff = 150 ms. Phantom experiments demonstrated that TE eff ‐dependent FSE signal progression can be characterized by T 2,eff values typically 40% longer than actual T 2 values, allowing accurate prediction of optimal TE eff within 2%–5%. Applied to PCa imaging, in vivo measurements indicated that effective T 2 relaxation times of the prostate are on average 1.5× longer than published T 2 values. Data Conclusion The benefits of TE eff = 150 ms versus 100 ms in prostate T2W FSE were supported by reader preference, phantom experiments, in vivo measurements, and analytic optimizations. Evidence Level 2. Technical Efficacy 2.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
- Department of Physics, Gustavus Adolphus College, St. Peter, Minnesota, USA.
- Department of Radiology, Mayo Clinic, Phoenix, Arizona, USA.
ORCID-Profile: Dahan Kim, Eric A Borisch, Akira Kawashima, Naoki Takahashi, Stephen J Riederer
Förderung
- NCRR NIH HHS
- NIBIB NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Kim, D., Pabi, R., Borisch, E. A., Froemming, A. T., Grimm, R. C., Hassanzadeh, S., Kawashima, A., Kido, A., Takahashi, N., Thomas, J. V., & Riederer, S. J. (2026). Optimal Selection of the Effective Echo Time ( TE eff ) for T2 ‐Weighted Fast‐Spin‐Echo MRI of the Prostate at 3.0 T: Effect on Lesion Conspicuity. Journal of Magnetic Resonance Imaging, 64(3), 616-628. https://doi.org/10.1002/jmri.70351
Vancouver
Kim D, Pabi R, Borisch EA, Froemming AT, Grimm RC, Hassanzadeh S, et al. Optimal Selection of the Effective Echo Time ( TE eff ) for T2 ‐Weighted Fast‐Spin‐Echo MRI of the Prostate at 3.0 T: Effect on Lesion Conspicuity. Journal of Magnetic Resonance Imaging. 2026;64(3):616-628. doi:10.1002/jmri.70351
BibTeX
@article{Kim2026,
author = {Kim, Dahan and Pabi, Ronard and Borisch, Eric A and Froemming, Adam T and Grimm, Roger C and Hassanzadeh, Sara and Kawashima, Akira and Kido, Ayumu and Takahashi, Naoki and Thomas, John V and Riederer, Stephen J},
title = {Optimal Selection of the Effective Echo Time ( TE eff ) for T2 ‐Weighted Fast‐Spin‐Echo MRI of the Prostate at 3.0 T: Effect on Lesion Conspicuity},
journal = {Journal of Magnetic Resonance Imaging},
year = {2026},
volume = {64},
number = {3},
pages = {616--628},
doi = {10.1002/jmri.70351}
}
EUVIMED