Deep Learning Reconstruction on Quantitative Analysis in Brain Tumors With Diffusion‐Weighted Imaging and Dynamic Susceptibility Contrast Imaging
Journal of Magnetic Resonance Imaging · 2026-06 · 63 (6) · 1586-1595
DOI: 10.1002/jmri.70286 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, online erschienen am 07.03.2026. Verfasst von E-Nae Cheong und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Brain Neoplasms, Diffusion Magnetic Resonance Imaging, Deep Learning, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: National Research Foundation of Korea (NRF).
Abstract (Originalsprache)
Background
Although deep learning reconstruction (DLR) has been shown to improve image quality in MRI, its impact on quantitative physiologic parameters derived from diffusion‐weighted imaging (DWI) and dynamic susceptibility contrast (DSC) perfusion in brain tumor imaging remains unclear.
Purpose
To evaluate the impact of DLR on quantitative parameters derived from DWI and DSC in patients with brain tumors. Study Type Retrospective. Subjects Sixty‐two patients (33 male) with post‐radiation brain metastasis. Field Strength/Sequence 3.0 T; T2, FLAIR, T1WI, DWI, DSC perfusion, and contrast‐enhanced T1WI. Assessment DWI and DSC images were reconstructed at three DLR levels (high, medium, and low). Agreement between original and DLR images for apparent diffusion coefficient (ADC), cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and time to peak (TTP) was assessed using the coefficient of variation, repeatability coefficient (RC), and concordance correlation coefficient. For DSC time‐series, signal‐to‐noise ratio, root mean square error (RMSE), and mean absolute error (MAE) were computed within tumor masks. DWI comparisons used mean signal intensity at b = 0 and b = 1000. Statistical Tests Paired t ‐tests compared ADC, relative CBV, and DWI signals. RMSE and MAE were compared using repeated‐measures analysis of variance. Significance was set at p < 0.05.
Results
ADC ( p = 0.955–0.979) and CBV ( p = 0.341–0.708), CBF ( p = 0.684–0.983), and MTT ( p = 0.403–0.971) values showed no significant differences between original and DLR images, while high‐level DLR showed significantly higher TTP than original images. RCs demonstrated high reproducibility across DLR levels for ADC (21.78–22.20), CBV (0.88–0.96), CBF (27.98–34.18), MTT (1.26–1.50), and TTP (3.40–3.99). DSC analysis showed the best noise reduction with high‐level DLR (lowest RMSE, 254.62 and MAE, 253.18 of DSC) without compromising CBV quantification. Data Conclusion DLR effectively reduced noise in DWI and DSC while preserving quantitative accuracy of ADC, CBV, CBF, and MTT. DLR may enable robust physiological MRI when applied in brain tumor imaging. Level of Evidence 3. Technical Efficacy Stage 3.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.
- AIRS Medical Inc., Seoul, Republic of Korea.
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, Maryland, USA.
ORCID-Profile: Yangsean Choi, Ji Eun Park
Förderung
- National Research Foundation of Korea (NRF)
Zitieren
APA
Cheong, E. N., Jeong, G., Park, J., Kim, H. J., Kim, J. J., Choi, Y., Jung, S. C., Kim, H. S., & Park, J. E. (2026). Deep Learning Reconstruction on Quantitative Analysis in Brain Tumors With Diffusion‐Weighted Imaging and Dynamic Susceptibility Contrast Imaging. Journal of Magnetic Resonance Imaging, 63(6), 1586-1595. https://doi.org/10.1002/jmri.70286
Vancouver
Cheong EN, Jeong G, Park J, Kim HJ, Kim JJ, Choi Y, et al. Deep Learning Reconstruction on Quantitative Analysis in Brain Tumors With Diffusion‐Weighted Imaging and Dynamic Susceptibility Contrast Imaging. Journal of Magnetic Resonance Imaging. 2026;63(6):1586-1595. doi:10.1002/jmri.70286
BibTeX
@article{Cheong2026,
author = {Cheong, E-Nae and Jeong, Geunu and Park, Jiyeon and Kim, Hye Jeong and Kim, Jeong Jin and Choi, Yangsean and Jung, Seung Chai and Kim, Ho Sung and Park, Ji Eun},
title = {Deep Learning Reconstruction on Quantitative Analysis in Brain Tumors With Diffusion‐Weighted Imaging and Dynamic Susceptibility Contrast Imaging},
journal = {Journal of Magnetic Resonance Imaging},
year = {2026},
volume = {63},
number = {6},
pages = {1586--1595},
doi = {10.1002/jmri.70286}
}
EUVIMED