EUVIMEDEUVIMED entdecken
Crossref

Deep Learning for Differentiating Benign From Malignant Bile Duct Dilation on MRCP : Development and Prospective Evaluation of an Xception‐Logistic Regression Ensemble Model

Jiong Liu, Lihong Li, Jing Zhang, Chunmei Yang, Xinqiao Huang, Yue Shu, Xiaopeng He, Jian Shu iD

Journal of Magnetic Resonance Imaging · 2025

DOI: 10.1002/jmri.70200 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2025. Verfasst von Jiong Liu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The Affiliated Hospital, Southwest Medical University, Luzhou, Sichuan, China. Hauptthemen laut MEDLINE: Deep Learning, Cholangiopancreatography, Magnetic Resonance, Bile Ducts, Bile Duct Neoplasms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Sichuan Province Science and Technology Support Program, National Natural Science Foundation of China, Sichuan Provincial Science and Technology Support Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate identification of benign and malignant bile duct dilatation (BDD) is needed to determine its management plan. Conventional imaging evaluation is subjective, whereas deep learning (DL) offers potential for automated objective assessment.

Purpose

To construct and evaluate DL models and ensemble strategies based on magnetic resonance cholangiopancreatography (MRCP) images for identifying benign and malignant BDD. Study Type Retrospective and prospective. Population A retrospective cohort ( n = 378; median age, 60 years [range: 14, 90]; 194 male) from two institutions and a prospective cohort ( n = 60; median age, 62.5 years [range: 15, 86]; 30 male) were included. Retrospective data were randomly stratified split into training, validation, and internal test sets (2:1:1) and an independent external test set. Benign cases were downsampled to balance class distribution. Field Strength/Sequence 3 T MRCP (3D turbo spin echo: VISTA and SPACE). Assessment The primary retrospective endpoint was area under the curve (AUC) across DL algorithms and ensembles. Prospectively, the accuracy, sensitivity, and specificity of the model was compared with those of three radiologists. Statistical Tests Group comparisons used Mann–Whitney U and Chi‐square tests ( p < 0.05). Model performance was evaluated using the Hosmer–Lemeshow test, DeLong's test with Bonferroni correction ( α = 0.005), and McNemar's test.

Results

The Xception model achieved AUCs of 0.816 (95% CI, 0.788–0.844) on the internal test set and 0.807 (95% CI, 0.779–0.835) on the external test set. The ensemble model incorporating logistic regression yielded higher patient‐level AUCs of 0.890 and 0.885, with good calibration ( p = 0.109). No significant differences were observed among the five ensemble strategies (minimum adjusted p = 0.62). In the prospective cohort, the model showed 90.0% accuracy, sensitivity, and specificity, comparable to radiologists (76.7%–86.7%) without a significant difference ( p = 0.143, 0.302, and 0.774, respectively). Data Conclusion The Xce‐LR model shows potential for automating BDD differentiation using MRCP. Level of Evidence 2. Technical Efficacy Stage 2.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningCholangiopancreatography, Magnetic ResonanceBile DuctsBile Duct NeoplasmsHumansMaleMiddle AgedFemaleProspective StudiesAgedRetrospective StudiesAdultAged, 80 and overDiagnosis, DifferentialAdolescentYoung AdultLogistic ModelsReproducibility of ResultsDilatation, PathologicSensitivity and SpecificityImage Interpretation, Computer-Assisted

Stichwörter der Autor:innen

bile duct dilationdeep learningdiagnosisensemble modelmagnetic resonance cholangiopancreatography

Autor:innen und Institutionen

  • Department of Radiology, The Affiliated Hospital, Southwest Medical University, Luzhou, Sichuan, China.
  • Precision Imaging and Intelligent Analysis Key Laboratory of Luzhou, Southwest Medical University, Luzhou, Sichuan, China.
  • Department of Oncology, The Affiliated Hospital, Southwest Medical University, Luzhou, Sichuan, China.

ORCID-Profile: Jian Shu

Förderung

  • Sichuan Province Science and Technology Support Program
  • National Natural Science Foundation of China
  • Sichuan Provincial Science and Technology Support Program

Zitieren

APA

Liu, J., Li, L., Zhang, J., Yang, C., Huang, X., Shu, Y., He, X., & Shu, J. (2025). Deep Learning for Differentiating Benign From Malignant Bile Duct Dilation on MRCP : Development and Prospective Evaluation of an Xception‐Logistic Regression Ensemble Model. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.70200

Vancouver

Liu J, Li L, Zhang J, Yang C, Huang X, Shu Y, et al. Deep Learning for Differentiating Benign From Malignant Bile Duct Dilation on MRCP : Development and Prospective Evaluation of an Xception‐Logistic Regression Ensemble Model. Journal of Magnetic Resonance Imaging. 2025. doi:10.1002/jmri.70200

BibTeX
@article{Liu2025,
  author = {Liu, Jiong and Li, Lihong and Zhang, Jing and Yang, Chunmei and Huang, Xinqiao and Shu, Yue and He, Xiaopeng and Shu, Jian},
  title = {Deep Learning for Differentiating Benign From Malignant Bile Duct Dilation on MRCP : Development and Prospective Evaluation of an Xception‐Logistic Regression Ensemble Model},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1002/jmri.70200}
}
Kostenlos starten →