EUVIMEDEUVIMED entdecken
Crossref

MRI sequence focused on pancreatic morphology evaluation: three-shot turbo spin-echo with deep learning-based reconstruction

Yoshisuke Kadoya iD, Kentaro Mochizuki, Akihiro Asano, Kosuke Miyakawa, Mao Kanatani, Junko Saito, Hitoshi Abo

Acta Radiologica · 2025

DOI: 10.1177/02841851251355844 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Radiologica, 2025. Verfasst von Yoshisuke Kadoya und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Radiology, Toyama Prefectural Central Hospital, Toyama, Japan. Hauptthemen laut MEDLINE: Deep Learning, Pancreas, Magnetic Resonance Imaging, Image Interpretation, Computer-Assisted. Die Arbeit nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Higher-resolution magnetic resonance imaging sequences are needed for the early detection of pancreatic cancer.

Purpose

To compare the quality of our novel T2-weighted, high-contrast, thin-slice imaging sequence, with an improved spatial resolution and deep learning-based reconstruction (three-shot turbo spin-echo with deep learning-based reconstruction [3S-TSE-DLR]), for imaging the pancreas with imaging using three conventional sequences (half-Fourier acquisition single-shot turbo spin-echo [HASTE], fat-suppressed 3D T1-weighted [FS-3D-T1W] imaging, and magnetic resonance cholangiopancreatography [MRCP]). Material and Methods Pancreatic images of 50 healthy volunteers acquired with 3S-TSE-DLR, HASTE, FS-3D-T1W imaging, and MRCP were compared by two diagnostic radiologists. A 5-point scale was used for assessing motion artifacts, pancreatic margin sharpness, and the ability to identify the main pancreatic duct (MPD) on 3S-TSE-DLR, HASTE, and FS-3D-T1W imaging, respectively. The ability to identify MPD via MRCP was also evaluated.

Results

Artifact scores (the higher the score, the fewer the artifacts) were significantly higher for 3S-TSE-DLR than for HASTE, and significantly lower for 3S-TSE-DLR than for FS-3D-T1W imaging, for both radiologists. Sharpness scores were significantly higher for 3S-TSE-DLR than for HASTE and FS-3D-T1W imaging, for both radiologists. The rate of identification of MPD was significantly higher for 3S-TSE-DLR than for FS-3D-T1W imaging, for both radiologists, and significantly higher for 3S-TSE-DLR than for HASTE for one radiologist. The rate of identification of MPD was not significantly different between 3S-TSE-DLR and MRCP.

Conclusion

3S-TSE-DLR provides better image sharpness than conventional sequences, can identify MPD equally as well or better than HASTE, and shows identification performance comparable to that of MRCP.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningPancreasMagnetic Resonance ImagingImage Interpretation, Computer-AssistedHumansMaleFemaleAdultMiddle AgedCholangiopancreatography, Magnetic ResonanceImaging, Three-DimensionalHealthy VolunteersAgedPancreatic Neoplasms

Stichwörter der Autor:innen

T2-weighted pulse sequencedeep learning reconstructionmagnetic resonance imagingpancreatic morphologythree-shot turbo spin-echo

Autor:innen und Institutionen

  • Department of Diagnostic Radiology, Toyama Prefectural Central Hospital, Toyama, Japan.
  • Department of Diagnostic Radiology, Ishikawa Prefectural Central Hospital, Kanazawa, Japan.
  • Department of Medical Technology, Toyama Prefectural Central Hospital, Toyama, Japan.

ORCID-Profile: Yoshisuke Kadoya

Zitieren

APA

Kadoya, Y., Mochizuki, K., Asano, A., Miyakawa, K., Kanatani, M., Saito, J., & Abo, H. (2025). MRI sequence focused on pancreatic morphology evaluation: three-shot turbo spin-echo with deep learning-based reconstruction. Acta Radiologica. https://doi.org/10.1177/02841851251355844

Vancouver

Kadoya Y, Mochizuki K, Asano A, Miyakawa K, Kanatani M, Saito J, et al. MRI sequence focused on pancreatic morphology evaluation: three-shot turbo spin-echo with deep learning-based reconstruction. Acta Radiologica. 2025. doi:10.1177/02841851251355844

BibTeX
@article{Kadoya2025,
  author = {Kadoya, Yoshisuke and Mochizuki, Kentaro and Asano, Akihiro and Miyakawa, Kosuke and Kanatani, Mao and Saito, Junko and Abo, Hitoshi},
  title = {MRI sequence focused on pancreatic morphology evaluation: three-shot turbo spin-echo with deep learning-based reconstruction},
  journal = {Acta Radiologica},
  year = {2025},
  doi = {10.1177/02841851251355844}
}
Kostenlos starten →