Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2026. Verfasst von Timothy B Weng und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Dell Medical School, University of Texas at Austin, Austin, Texas, USA. Hauptthemen laut MEDLINE: Breath Holding, Magnetic Resonance Imaging, Head Movements, Head. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NHLBI NIH HHS, NINDS NIH HHS, NIA NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cerebrovascular reactivity reflects changes in cerebral blood flow in response to an acute stimulus and is reflective of the brain's ability to match blood flow to demand. Functional MRI with a breath‐hold task can be used to elicit this vasoactive response, but data validity hinges on subject compliance. Determining breath‐hold compliance often requires external monitoring equipment.

Purpose

To develop a non‐invasive and data‐driven quality filter for breath‐hold compliance using only measurements of head motion during imaging. Study Type Prospective cohort.

Participants

Longitudinal data from healthy middle‐aged subjects enrolled in the Coronary Artery Risk Development in Young Adults Brain MRI Study, N = 1141, 47.1% female. Field Strength/Sequence 3.0 Tesla gradient‐echo MRI. Assessment Manual labelling of respiratory belt monitored data was used to determine breath hold compliance during MRI scan. A model to estimate the probability of non‐compliance with the breath hold task was developed using measures of head motion. The model's ability to identify scans in which the participant was not performing the breath hold were summarized using performance metrics including sensitivity, specificity, recall, and F1 score. The model was applied to additional unmarked data to assess effects on population measures of CVR. Statistical Tests Sensitivity analysis revealed exclusion of non‐compliant scans using the developed model did not affect median cerebrovascular reactivity (Median [q1, q3] = 1.32 [0.96, 1.71]) compared to using manual review of respiratory belt data (1.33 [1.02, 1.74]) while reducing interquartile range.

Results

The final model based on a multi‐layer perceptron machine learning classifier estimated non‐compliance with an accuracy of 76.9% and an F1 score of 69.5%, indicating a moderate balance between precision and recall for the identification of scans in which the participant was not compliant. Data Conclusion The developed model provides the probability of non‐compliance with a breath‐hold task, which could later be used as a quality filter or included in statistical analyses. Level of Evidence 1. Technical Efficacy Stage 3.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breath HoldingMagnetic Resonance ImagingHead MovementsHeadBrainHumansFemaleMaleProspective StudiesAdultMiddle AgedMotionCerebrovascular CirculationLongitudinal StudiesImage Processing, Computer-AssistedSensitivity and SpecificityComplianceReproducibility of Results

Stichwörter der Autor:innen

breath holdcerebrovascular reactivitydata qualityfMRI

Autor:innen und Institutionen

  • Department of Neurology, Dell Medical School, University of Texas at Austin, Austin, Texas, USA.
  • Department of Radiology, University of Pennsylvania Health System, Philadelphia, Pennsylvania, USA.
  • Henry H. Wheeler Jr. Brain Imaging Center, University of California, Berkeley, Berkeley, California, USA.
  • Division of Epidemiology and Community Health, University of Minnesota, Minneapolis, Minnesota, USA.
  • Department of Neurology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.
  • Kaiser Permanente Medical Center Program, Oakland, California, USA.

ORCID-Profile: Adrienne N Dula

Förderung

  • NHLBI NIH HHS
  • NINDS NIH HHS
  • NIA NIH HHS
  • National Institute on Aging
  • National Institute of Neurological Disorders and Stroke
  • National Heart, Lung, and Blood Institute

Zitieren

APA

Weng, T. B., Porwal, G., Srinivasan, D., Inglis, B., Rodriguez, S., Jacobs, D. R., Schreiner, P. J., Sorond, F. A., Sidney, S., Lewis, C., Launer, L., Erus, G., Nasrallah, I. M., Bryan, R. N., & Dula, A. N. (2026). Predicting Breath Hold Task Compliance From Head Motion. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.70105

Vancouver

Weng TB, Porwal G, Srinivasan D, Inglis B, Rodriguez S, Jacobs DR, et al. Predicting Breath Hold Task Compliance From Head Motion. Journal of Magnetic Resonance Imaging. 2026. doi:10.1002/jmri.70105

BibTeX
@article{Weng2026,
  author = {Weng, Timothy B and Porwal, Gargi and Srinivasan, Dhivya and Inglis, Ben and Rodriguez, Sabrina and Jacobs, David R and Schreiner, Pamela J and Sorond, Farzaneh A and Sidney, Stephen and Lewis, Cora and Launer, Lenore and Erus, Guray and Nasrallah, Ilya M and Bryan, R Nick and Dula, Adrienne N},
  title = {Predicting Breath Hold Task Compliance From Head Motion},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2026},
  doi = {10.1002/jmri.70105}
}
Kostenlos starten →