Magnetic Resonance Elastography Combined With PI ‐ RADS v2.1 for the Identification of Clinically Significant Prostate Cancer

Jie Chen, Yuntian Chen, Guoyong Chen, Liping Deng, Yuan Yuan, Hehan Tang, Zhen Zhang, Tingyu Chen, Hao Zeng, Enyu Yuan, Meng Yin, Jun Chen and 2 more

Journal of Magnetic Resonance Imaging · 2025-05 · 61 (5) · 2248-2257

DOI: 10.1002/jmri.29653 ↗

At a glance

Journal article in Journal of Magnetic Resonance Imaging, published online on 2024-11-08. Written by Jie Chen and 13 co-authors. Institution: Department of Radiology, West China Hospital of Sichuan University, Chengdu, China. Major MEDLINE topics: Prostatic Neoplasms, Elasticity Imaging Techniques, Magnetic Resonance Imaging. Cited 7 times so far (Crossref); 26 references. The full text is freely available in PubMed Central. Funded by: The Department of Defense (DoD) award, The Post-Doctor Research Project, West China Hospital of Sichuan University, NIBIB NIH HHS.

ResumenSubjectsDatos bibliográficosCiteRelated studies

Abstract (original language)

Background

Multiparametric MRI may cause overdiagnosis of clinically significant prostate cancer (csPCa) with the Prostate Imaging Reporting and Data System version 2.1 (PI‐RADS v2.1).

Objectives

To investigate the diagnostic performance of stiffness as a standalone and complementary marker to PI‐RADS v2.1 for diagnosing csPCa. Study Type Prospective. Subjects One hundred forty‐seven participants with pathologically confirmed prostate lesions (≥1 cm), including 71 with csPCa. Field Strength/Sequence T1‐weighted fast spin‐echo, T2‐weighted fast spin‐echo, single‐shot echo‐planar diffusion‐weighted imaging, fast 3D gradient‐echo T1‐weighted dynamic contrast‐enhanced imaging, and 3D single‐shot spin‐echo based echo‐planar MR elastography at 3.0 T. Assessment The PI‐RADS v2.1 score was assessed by three radiologists independently. Lesion shear stiffness (SS) values at 60 Hz and 90 Hz were measured. A modified PI‐RADS integrating stiffness with PI‐RADS v2.1 was developed. Diagnostic performance for csPCa was compared between stiffness, PI‐RADS v2.1 and the modified PI‐RADS. Statistical Test Spearman's correlation, Fleiss κ and intraclass correlation, Pearson correlation, one‐way analysis of variance, area under the receiver operating characteristic curve (AUC), and the Delong test. Significance level was P < 0.05.

Results

In the peripheral zone, csPCa (N = 35) had significantly higher SS than non‐csPCa at 60 Hz (3.22 ± 0.66 kPa vs. 2.56 ± 0.56 kPa) and at 90 Hz (5.64 ± 1.30 kPa vs. 4.48 ± 0.84 kPa). PI‐RADS v2.1 showed 100% sensitivity, 58% specificity, and 0.79 AUC for detecting csPCa. SS achieved 97% sensitivity, 52% specificity, and 0.80 AUC at 60 Hz, while SS had 63% sensitivity, 87% specificity, and 0.78 AUC at 90 Hz. The modified PI‐RADS, combing SS at 60 Hz with PI‐RADS v2.1, resulted in a significantly increased AUC (0.86) compared to that of PI‐RADS v2.1, with a sensitivity of 97% and specificity of 75%. Data Conclusion Stiffness can help identifying csPCa in the peripheral zone. Combining stiffness with the PI‐RADS v2.1 improved the diagnostic accuracy and specificity for csPCa. Evidence Level 1 Technical Efficacy Stage 2

Subjects

MeSH terms (MEDLINE)

Prostatic NeoplasmsElasticity Imaging TechniquesMagnetic Resonance ImagingHumansMaleMiddle AgedAgedProspective StudiesSensitivity and SpecificityReproducibility of ResultsProstateROC CurveImage Interpretation, Computer-AssistedAged, 80 and overImaging, Three-Dimensional

Author keywords

Prostate Imaging Reporting and Data Systemclinically significant prostate cancerelastography

Authors and institutions

  • Department of Radiology, West China Hospital of Sichuan University, Chengdu, China.
  • Department of Radiology, Functional and Molecular Imaging Key Laboratory of Sichuan Province, West China Hospital, Sichuan University, Chengdu, China.
  • Department of Urology, West China Hospital of Sichuan University, Chengdu, China.
  • Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
  • Department of Radiology, The Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing, China.

ORCID profiles: Bin Song, Jin Yao

Funding

  • The Department of Defense (DoD) award
  • The Post-Doctor Research Project, West China Hospital of Sichuan University
  • NIBIB NIH HHS
  • The National Nature Science Foundation of China
  • The Science and Technology Support Program of Sichuan Province
  • The Post-Doctoral Station Development project of Sanya
  • The 1.3.5 project for disciplines of excellence at West China Hospital, Sichuan University
  • U.S. Department of Defense

Cite

APA

Chen, J., Chen, Y., Chen, G., Deng, L., Yuan, Y., Tang, H., Zhang, Z., Chen, T., Zeng, H., Yuan, E., Yin, M., Chen, J., Song, B., & Yao, J. (2025). Magnetic Resonance Elastography Combined With PI ‐ RADS v2.1 for the Identification of Clinically Significant Prostate Cancer. Journal of Magnetic Resonance Imaging, 61(5), 2248-2257. https://doi.org/10.1002/jmri.29653

Vancouver

Chen J, Chen Y, Chen G, Deng L, Yuan Y, Tang H, et al. Magnetic Resonance Elastography Combined With PI ‐ RADS v2.1 for the Identification of Clinically Significant Prostate Cancer. Journal of Magnetic Resonance Imaging. 2025;61(5):2248-2257. doi:10.1002/jmri.29653

BibTeX
@article{Chen2025,
  author = {Chen, Jie and Chen, Yuntian and Chen, Guoyong and Deng, Liping and Yuan, Yuan and Tang, Hehan and Zhang, Zhen and Chen, Tingyu and Zeng, Hao and Yuan, Enyu and Yin, Meng and Chen, Jun and Song, Bin and Yao, Jin},
  title = {Magnetic Resonance Elastography Combined With PI ‐ RADS v2.1 for the Identification of Clinically Significant Prostate Cancer},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2025},
  volume = {61},
  number = {5},
  pages = {2248--2257},
  doi = {10.1002/jmri.29653}
}
Start for free →