EUVIMEDEUVIMED entdecken
Open Access

Improving Accuracy and Reproducibility of Cartilage T 2 Mapping in the OAI Dataset Through Extended Phase Graph Modeling

Marco Barbieri iD, Anthony A Gatti, Feliks Kogan

Journal of Magnetic Resonance Imaging · 2025-05 · 61 (5) · 2116-2127

DOI: 10.1002/jmri.29646 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, online erschienen am 28.10.2024. Verfasst von Marco Barbieri und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Stanford University, Stanford, California, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Cartilage, Articular, Osteoarthritis, Knee. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NIAMS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The Osteoarthritis Initiative (OAI) collected extensive imaging data, including Multi‐Echo Spin‐Echo (MESE) sequences for measuring knee cartilage T 2 relaxation times. Mono‐exponential models are used in the OAI for T 2 fitting, which neglects stimulated echoes and B 1 inhomogeneities. Extended Phase Graph (EPG) modeling addresses these limitations but has not been applied to the OAI dataset.

Purpose

To assess how different fitting methods, including EPG‐based and exponential‐based approaches, affect the accuracy and reproducibility of cartilage T 2 in the OAI dataset. Study Type Retrospective. Population From OAI dataset, 50 subjects, stratified by osteoarthritis (OA) severity using Kellgren–Lawrence grades (KLG), and 50 subjects without OA diagnosis during OAI duration were selected (each group: 25 females, mean ages ~61 years). Field Strength/Sequence 3‐T, two‐dimensional (2D) MESE sequence. Assessment Femoral and tibial cartilages were segmented from DESS images, subdivided into seven sub‐regions, and co‐registered to MESE. T 2 maps were obtained using three EPG‐based methods (nonlinear least squares, dictionary matching, and deep learning) and three mono‐exponential approaches (linear least squares, nonlinear least squares, and noise‐corrected exponential). Average T 2 values within sub‐regions were obtained. Pair‐wise agreement among fitting methods was evaluated using the stratified subjects, while reproducibility using healthy subjects. Each method's T 2 accuracy and repeatability varying signal‐to‐noise ratio (SNR) were assessed with simulations. Statistical Tests Bland–Altman analysis, Lin's concordance coefficient, and coefficient of variation assessed agreement, repeatability, and reproducibility. Statistical significance was set at P ‐value 100) compared to mono‐exponential methods (error > 7 msec). EPG‐based approaches had better reproducibility, with limits of agreement 1.5–5 msec narrower than exponential‐based methods. T 2 values from EPG methods were systematically 10–17 msec lower than those from mono‐exponential fitting. Data Conclusion EPG modeling improved agreement and reproducibility of cartilage T 2 mapping in subjects from the OAI dataset. Evidence Level 3 Technical Efficacy Stage 1

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingCartilage, ArticularOsteoarthritis, KneeHumansFemaleReproducibility of ResultsMiddle AgedMaleRetrospective StudiesAgedKnee JointAlgorithmsImage Processing, Computer-AssistedImage Interpretation, Computer-Assisted

Stichwörter der Autor:innen

MESEOsteoarthritis InitiativeT2 mappingknee imagingosteoarthritis

Autor:innen und Institutionen

  • Department of Radiology, Stanford University, Stanford, California, USA.

ORCID-Profile: Marco Barbieri

Förderung

  • NIBIB NIH HHS
  • NIAMS NIH HHS

Zitieren

APA

Barbieri, M., Gatti, A. A., & Kogan, F. (2025). Improving Accuracy and Reproducibility of Cartilage T 2 Mapping in the OAI Dataset Through Extended Phase Graph Modeling. Journal of Magnetic Resonance Imaging, 61(5), 2116-2127. https://doi.org/10.1002/jmri.29646

Vancouver

Barbieri M, Gatti AA, Kogan F. Improving Accuracy and Reproducibility of Cartilage T 2 Mapping in the OAI Dataset Through Extended Phase Graph Modeling. Journal of Magnetic Resonance Imaging. 2025;61(5):2116-2127. doi:10.1002/jmri.29646

BibTeX
@article{Barbieri2025,
  author = {Barbieri, Marco and Gatti, Anthony A and Kogan, Feliks},
  title = {Improving Accuracy and Reproducibility of Cartilage T 2 Mapping in the OAI Dataset Through Extended Phase Graph Modeling},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2025},
  volume = {61},
  number = {5},
  pages = {2116--2127},
  doi = {10.1002/jmri.29646}
}
Kostenlos starten →