EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Simultaneous Multiparameter Mapping of the Liver in a Single Breath‐Hold or Respiratory‐Triggered Acquisition Using Multi‐Inversion Spin and Gradient Echo MRI

Mary Kate Manhard iD, Anandh Kilpattu Ramaniharan iD, Jean A Tkach iD, Andrew T Trout iD, Jonathan R Dillman iD, Amol S Pednekar

Journal of Magnetic Resonance Imaging · 2025

DOI: 10.1002/jmri.29584 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2025. Verfasst von Mary Kate Manhard und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA. Hauptthemen laut MEDLINE: Breath Holding, Liver, Magnetic Resonance Imaging, Liver Diseases. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Quantitative parametric mapping is an increasingly important tool for noninvasive assessment of chronic liver disease. Conventional parametric mapping techniques require multiple breath‐held acquisitions and provide limited anatomic coverage.

Purpose

To investigate a multi‐inversion spin and gradient echo (MI‐SAGE) technique for simultaneous estimation of T 1 , T 2 , and T 2 * of the liver. Study Type Prospective. Subjects Sixteen research participants, both adult and pediatric (age 17.5 ± 4.6 years, eight male), with and without known liver disease (seven asymptomatic healthy controls, two fibrotic liver disease, five steatotic liver disease, and two fibrotic and steatotic liver disease). Field Strength/Sequence 1.5 T, single breath‐hold and respiratory triggered MI‐SAGE, breath‐hold modified Look–Locker inversion recovery (MOLLI, T 1 mapping), breath‐hold gradient and spin echo (GRASE, T 2 mapping), and multiple gradient echo (mGRE, T 2 * mapping) sequences. Assessment Agreement between hepatic T 1 , T 2 , and T 2 * estimated using MI‐SAGE and conventional parametric mapping sequences was evaluated. Repeatability and reproducibility of MI‐SAGE were evaluated using a same‐session acquisition and second‐session acquisition. Statistical Tests Bland–Altman analysis with bias assessment and limits of agreement (LOA) and intraclass correlation coefficients (ICC).

Results

Hepatic T 1 , T 2 , and T 2 * estimates obtained using the MI‐SAGE technique had mean biases of 72 (LOA: −22 to 166) msec, −3 (LOA: −10 to 5) msec, and 2 (LOA: −5 to 8) msec (single breath‐hold) and 36 (LOA: −43 to 120) msec, −3 (LOA: −17 to 11) msec, and 4 (LOA: −3 to 11) msec (respiratory triggered), respectively, in comparison to conventional acquisitions using MOLLI, GRASE, and mGRE. All MI‐SAGE estimates had strong repeatability and reproducibility (ICC > 0.72). Data Conclusion Hepatic T 1 , T 2 , and T 2 * estimates obtained using an MI‐SAGE technique were comparable to conventional methods, although there was a 12%/6% for breath‐hold/respiratory triggered underestimation of T 1 values compared to MOLLI. Both respiratory triggered and breath‐hold MI‐SAGE parameter maps demonstrated strong repeatability and reproducibility. Level of Evidence 1 Technical Efficacy Stage 2

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breath HoldingLiverMagnetic Resonance ImagingLiver DiseasesHumansMaleFemaleReproducibility of ResultsProspective StudiesAdolescentAdultYoung AdultChildImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedRespiration

Stichwörter der Autor:innen

free breathingliverquantitative MRIrapid relaxometry

Autor:innen und Institutionen

  • Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.
  • Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA.

ORCID-Profile: Mary Kate Manhard, Anandh Kilpattu Ramaniharan, Jean A Tkach, Andrew T Trout, Jonathan R Dillman

Zitieren

APA

Manhard, M. K., Kilpattu Ramaniharan, A., Tkach, J. A., Trout, A. T., Dillman, J. R., & Pednekar, A. S. (2025). Simultaneous Multiparameter Mapping of the Liver in a Single Breath‐Hold or Respiratory‐Triggered Acquisition Using Multi‐Inversion Spin and Gradient Echo MRI. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29584

Vancouver

Manhard MK, Kilpattu Ramaniharan A, Tkach JA, Trout AT, Dillman JR, Pednekar AS. Simultaneous Multiparameter Mapping of the Liver in a Single Breath‐Hold or Respiratory‐Triggered Acquisition Using Multi‐Inversion Spin and Gradient Echo MRI. Journal of Magnetic Resonance Imaging. 2025. doi:10.1002/jmri.29584

BibTeX
@article{Manhard2025,
  author = {Manhard, Mary Kate and Kilpattu Ramaniharan, Anandh and Tkach, Jean A and Trout, Andrew T and Dillman, Jonathan R and Pednekar, Amol S},
  title = {Simultaneous Multiparameter Mapping of the Liver in a Single Breath‐Hold or Respiratory‐Triggered Acquisition Using Multi‐Inversion Spin and Gradient Echo MRI},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1002/jmri.29584}
}
Kostenlos starten →