MRI Reference Ranges for Fetal Cardiothoracic Ratio of Diameter, Area, and Circumference from 21 to 38 Weeks Gestational Age
Journal of Magnetic Resonance Imaging · 2025
DOI: 10.1002/jmri.29482 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2025. Verfasst von Duo Gao und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging, The Second Hospital of Hebei Medical University, Shijiazhuang, Hebei Province, China. Hauptthemen laut MEDLINE: Gestational Age, Magnetic Resonance Imaging, Fetal Heart. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Roentgen Imaging Research Project, S&T Program of Hebei, The fund of the Second Hospital of Hebei Medical University.
Abstract (Originalsprache)
Background
Whether fetal cardiothoracic ratio (CTR) is constant or increasing with gestational age (GA) is controversial. The majority of the fetal CTR data has been obtained through ultrasound.
Purpose
To retrospectively analyze CTR of diameter, area, and circumference on prenatal MR images in a low‐risk population of singleton pregnancies, and to clarify its diagnostic value. Study Type Retrospective. Subjects 1024 low‐risk singleton pregnancies undergoing MRI. Field Strength Balanced steady state free precession sequence and single shot‐fast spin echo sequence at 1.5 Tesla. Assessment Pregnancy clinical data were recorded and diameter, area, and circumference of the fetal heart and thorax were measured by two researchers with 6 and 7 years of radiology experience, respectively, and their variation with GA was investigated. The relationship between CTRs with GA was also investigated. Finally, the value of CTR in the diagnosis of fetuses with abnormal development was explored by using receiver operating characteristic (ROC) curves. Statistical Tests Linear regression and ROC curves. A P value 0.7, P < 0.0001) between the diameter, area, and circumference of the heart and thorax with GA. The CTRs remain constant values and do not change with GA. The 5th, 50th, and 95th percentiles of the CTR in 21–38 weeks GA were 0.32, 0.39, and 0.48 respectively. The corresponding percentiles for the area ratio were 0.15, 0.21 and 0.27, respectively, and for the circumference ratio were 0.40, 0.46, and 0.52, respectively. Based on ROC curves of CTR with three methods, the area under curves (AUCs) were up to 0.95, the sensitivity and the specificity were more than 88%. Data Conclusion Reference ranges of fetal CTR were established using MRI , which remain constant. These may be helpful in making a definitive diagnosis in fetuses with abnormal development. Level of Evidence 4. Technical Efficacy Stage 2.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Imaging, The Second Hospital of Hebei Medical University, Shijiazhuang, Hebei Province, China.
ORCID-Profile: Duo Gao, Yimin Cao, Zuojun Geng, Lixia Zhou
Förderung
- Roentgen Imaging Research Project
- S&T Program of Hebei
- The fund of the Second Hospital of Hebei Medical University
Zitieren
APA
Gao, D., Feng, X., Cao, Y., Yi, Z., Han, X., Yang, H., Geng, Z., & Zhou, L. (2025). MRI Reference Ranges for Fetal Cardiothoracic Ratio of Diameter, Area, and Circumference from 21 to 38 Weeks Gestational Age. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29482
Vancouver
Gao D, Feng X, Cao Y, Yi Z, Han X, Yang H, et al. MRI Reference Ranges for Fetal Cardiothoracic Ratio of Diameter, Area, and Circumference from 21 to 38 Weeks Gestational Age. Journal of Magnetic Resonance Imaging. 2025. doi:10.1002/jmri.29482
BibTeX
@article{Gao2025,
author = {Gao, Duo and Feng, Xuran and Cao, Yimin and Yi, Zexi and Han, Xuefang and Yang, Haiqing and Geng, Zuojun and Zhou, Lixia},
title = {MRI Reference Ranges for Fetal Cardiothoracic Ratio of Diameter, Area, and Circumference from 21 to 38 Weeks Gestational Age},
journal = {Journal of Magnetic Resonance Imaging},
year = {2025},
doi = {10.1002/jmri.29482}
}
EUVIMED