EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Poor correlation of 2D shear wave elastography and transient elastography in Fontan‐associated liver disease: A head‐to‐head comparison

Madeleine Gill iD, Sanjivan Mudaliar iD, David Prince iD, Nwe Ni Than, Rachel Cordina, Avik Majumdar iD

JGH Open · 2023-10 · 7 (10) · 690-697

DOI: 10.1002/jgh3.12967 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JGH Open, online erschienen am 14.09.2023. Verfasst von Madeleine Gill und 5 weiteren Autor:innen. Beteiligte Einrichtung: Australian National Liver Transplant Unit Royal Prince Alfred Hospital Sydney New South Wales Australia. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Aims Fontan‐associated liver disease (FALD) is a long‐term complication of the Fontan procedure. Guidelines recommend elastography, but the utility of transient elastography (TE) and two‐dimensional shear wave elastography (2D SWE) is unknown. We aimed to evaluate the relationship between TE and 2D SWE in FALD.

Methods

This prospective cohort study included 25 patients managed in a specialist clinic between January 2018 and August 2021. Trained clinicians performed 2D SWE (GE Logiq‐E9) and TE (FibroScan 503 Touch) on the same day under the same conditions. Laboratory, echocardiography, and imaging data were collected. The atrioventricular systolic‐to‐diastolic duration (AVV S/D ratio) was calculated as a measure of cardiac diastolic function.

Results

We analyzed 40 paired measurements. Median age was 22 years. Median liver stiffness measurement (LSM) was 15.4 kPa (12.1–19.6) by TE and 8.0 kPa (7.0–10.3) ( P = 0.001) by 2D SWE. There was weak correlation between the modalities ( r = 0.41, P = 0.004). There was no correlation between time since Fontan and LSM by TE ( r = 0.15, P = 0.19) or 2D SWE ( r = 0.19, P = 0.13). There was no difference in LSM irrespective of whether sonographic cirrhosis was present or absent by TE (17.4 kPa [15.9–23.6] vs. 14.9 kPa [12.0–19.4], respectively, P = 0.6) or 2D SWE (9.0 kPa [2.8–10.5] vs. 8.0 kPa [6.7–10.1], P = 0.46). There was no correlation between AVV S/D ratio and LSM by TE ( r = 0.16, P = 0.18) or 2D SWE ( r = 0.02, P = 0.45).

Conclusions

In FALD, TE and 2D SWE are poorly correlated. LSM by either modality was not associated with known risk factors for liver fibrosis or Fontan function. Based on these data, the role of elastography in FALD is uncertain.

Schlagwörter

Stichwörter der Autor:innen

Fontancirrhosisechocardiographyelastographyfibrosisliver stiffness

Autor:innen und Institutionen

  • Australian National Liver Transplant Unit Royal Prince Alfred Hospital Sydney New South Wales Australia.
  • Faculty of Medicine and Health The University of Sydney Sydney New South Wales Australia.
  • Centenary Institute of Cancer Medicine and Cell Biology Sydney New South Wales Australia.
  • Department of Gastroenterology and Hepatology University Hospital Coventry Coventry UK.
  • Department of Cardiology Royal Prince Alfred Hospital Sydney New South Wales Australia.
  • Victorian Liver Transplant Unit, Austin Hospital Heidelberg Victoria Australia.

ORCID-Profile: Madeleine Gill, Sanjivan Mudaliar, David Prince, Avik Majumdar

Zitieren

APA

Gill, M., Mudaliar, S., Prince, D., Than, N. N., Cordina, R., & Majumdar, A. (2023). Poor correlation of 2D shear wave elastography and transient elastography in Fontan‐associated liver disease: A head‐to‐head comparison. JGH Open, 7(10), 690-697. https://doi.org/10.1002/jgh3.12967

Vancouver

Gill M, Mudaliar S, Prince D, Than NN, Cordina R, Majumdar A. Poor correlation of 2D shear wave elastography and transient elastography in Fontan‐associated liver disease: A head‐to‐head comparison. JGH Open. 2023;7(10):690-697. doi:10.1002/jgh3.12967

BibTeX
@article{Gill2023,
  author = {Gill, Madeleine and Mudaliar, Sanjivan and Prince, David and Than, Nwe Ni and Cordina, Rachel and Majumdar, Avik},
  title = {Poor correlation of 2D shear wave elastography and transient elastography in Fontan‐associated liver disease: A head‐to‐head comparison},
  journal = {JGH Open},
  year = {2023},
  volume = {7},
  number = {10},
  pages = {690--697},
  doi = {10.1002/jgh3.12967}
}
Kostenlos starten →