The use of a novel toe–thumb pressure index for assessing arterial status in the lower limb. A reliability and validity study
Journal of Foot and Ankle Research · 2024
DOI: 10.1002/jfa2.70011 ↗At a glance
Validierungsstudie in Journal of Foot and Ankle Research, 2024. Written by Juliana Mazzeo and 4 co-authors. Institution: Allied Health and Human Performance, Innovation, Implementation and Clinical Translation in Health (IIMPACT), University of South Australia, Adelaide…. Major MEDLINE topics: Thumb, Toes, Ankle Brachial Index. Cited 1 times so far (Crossref); 50 references. The full text is freely available (open access, CC BY 4.0). Funded by: Allied Health and Human Performance Unit, University of South Australia.
Abstract (original language)
Aims
This study explored the reliability, validity and perceived comfort of a novel thumb pressure measure and calculation of a toe–thumb index to identify their suitability as an adjunct or alternatives to ankle–brachial and toe–brachial indices. Methods and Results Repeated manual thumb and toe systolic blood pressures were conducted using two raters, over two time points, on 34 healthy participants. Concurrent automated toe, thumb and brachial systolic blood pressures as well as comfort ratings for these measures (using a 10 mm visual analogue scale) were captured once by a research assistant. Automated thumb and brachial measures showed fair correlation ( ρ = 0.36, p = 0.03) and a toe–thumb index and toe–brachial index good correlation ( ρ = 0.62, p < 0.01). Intraclass correlation coefficients (ICC) identified moderate intra‐rater reliability for manual thumb pressures for Rater 1 and 2 (ICC 0.57, 95% CI [0.14, 0.79] and ICC 0.74, 95% CI [0.49, 0.87], respectively), while inter‐rater reliability was poor (ICC = 0.16, 95% CI [−0.85, 0.47]). Concurrent validity comparing manual and automated measures for thumb pressure was also poor (ICC −0.05, 95% CI [−1.06, 0.72] and ICC 0.42, 95% CI [−0.16, 0.72] Rater 1 and 2 respectively). Thumb measures were significantly more comfortable than brachial measures (5 mm, p < 0.00).
Conclusion
Thumb systolic pressures are correlated with brachial systolic pressures, with reasonable intra‐rater reliability, however, correlation is only fair and measurement error wider than clinically acceptable. Furthermore, manual measures are poorly correlated with automated units. Consequently, caution is required in applying these techniques. As thumb measures were perceived as significantly more comfortable than brachial measures and have an advantage where brachial pressures cannot, or should not, be obtained, further evaluation is warranted.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Allied Health and Human Performance, Innovation, Implementation and Clinical Translation in Health (IIMPACT), University of South Australia, Adelaide, South Australia, Australia.
- School of Clinical and Molecular Sciences, Faculty of Medicine Nursing and Health, School of Clinical Sciences, Monash University, Clayton, Victoria, Australia.
- School of Health Sciences, College of Health Medicine and Wellbeing, University of Newcastle, New Castle, New South Wales, Australia.
- Allied Health and Human Performance, University of South Australia, Adelaide, South Australia, Australia.
ORCID profiles: Helen A Banwell, Peta E Tehan, Kristin Graham
Funding
- Allied Health and Human Performance Unit, University of South Australia
Cite
APA
Mazzeo, J., Banwell, H. A., Tehan, P. E., Anderson, G., & Graham, K. (2024). The use of a novel toe–thumb pressure index for assessing arterial status in the lower limb. A reliability and validity study. Journal of Foot and Ankle Research. https://doi.org/10.1002/jfa2.70011
Vancouver
Mazzeo J, Banwell HA, Tehan PE, Anderson G, Graham K. The use of a novel toe–thumb pressure index for assessing arterial status in the lower limb. A reliability and validity study. Journal of Foot and Ankle Research. 2024. doi:10.1002/jfa2.70011
BibTeX
@article{Mazzeo2024,
author = {Mazzeo, Juliana and Banwell, Helen A and Tehan, Peta E and Anderson, Grace and Graham, Kristin},
title = {The use of a novel toe–thumb pressure index for assessing arterial status in the lower limb. A reliability and validity study},
journal = {Journal of Foot and Ankle Research},
year = {2024},
doi = {10.1002/jfa2.70011}
}
EUVIMED