EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

The use of a novel toe–thumb pressure index for assessing arterial status in the lower limb. A reliability and validity study

Juliana Mazzeo, Helen A Banwell iD, Peta E Tehan iD, Grace Anderson, Kristin Graham iD

Journal of Foot and Ankle Research · 2024

DOI: 10.1002/jfa2.70011 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Foot and Ankle Research, 2024. Verfasst von Juliana Mazzeo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Allied Health and Human Performance, Innovation, Implementation and Clinical Translation in Health (IIMPACT), University of South Australia, Adelaide…. Hauptthemen laut MEDLINE: Thumb, Toes, Ankle Brachial Index. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Allied Health and Human Performance Unit, University of South Australia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

This study explored the reliability, validity and perceived comfort of a novel thumb pressure measure and calculation of a toe–thumb index to identify their suitability as an adjunct or alternatives to ankle–brachial and toe–brachial indices. Methods and Results Repeated manual thumb and toe systolic blood pressures were conducted using two raters, over two time points, on 34 healthy participants. Concurrent automated toe, thumb and brachial systolic blood pressures as well as comfort ratings for these measures (using a 10 mm visual analogue scale) were captured once by a research assistant. Automated thumb and brachial measures showed fair correlation ( ρ = 0.36, p = 0.03) and a toe–thumb index and toe–brachial index good correlation ( ρ = 0.62, p < 0.01). Intraclass correlation coefficients (ICC) identified moderate intra‐rater reliability for manual thumb pressures for Rater 1 and 2 (ICC 0.57, 95% CI [0.14, 0.79] and ICC 0.74, 95% CI [0.49, 0.87], respectively), while inter‐rater reliability was poor (ICC = 0.16, 95% CI [−0.85, 0.47]). Concurrent validity comparing manual and automated measures for thumb pressure was also poor (ICC −0.05, 95% CI [−1.06, 0.72] and ICC 0.42, 95% CI [−0.16, 0.72] Rater 1 and 2 respectively). Thumb measures were significantly more comfortable than brachial measures (5 mm, p < 0.00).

Conclusion

Thumb systolic pressures are correlated with brachial systolic pressures, with reasonable intra‐rater reliability, however, correlation is only fair and measurement error wider than clinically acceptable. Furthermore, manual measures are poorly correlated with automated units. Consequently, caution is required in applying these techniques. As thumb measures were perceived as significantly more comfortable than brachial measures and have an advantage where brachial pressures cannot, or should not, be obtained, further evaluation is warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ThumbToesAnkle Brachial IndexHumansReproducibility of ResultsMaleFemaleAdultPressureYoung AdultBlood Pressure DeterminationLower ExtremityBlood PressureMiddle AgedHealthy Volunteers

Stichwörter der Autor:innen

peripheral arterial diseasereliability studythumb pressuretoe‐brachial indexvalidity study

Autor:innen und Institutionen

  • Allied Health and Human Performance, Innovation, Implementation and Clinical Translation in Health (IIMPACT), University of South Australia, Adelaide, South Australia, Australia.
  • School of Clinical and Molecular Sciences, Faculty of Medicine Nursing and Health, School of Clinical Sciences, Monash University, Clayton, Victoria, Australia.
  • School of Health Sciences, College of Health Medicine and Wellbeing, University of Newcastle, New Castle, New South Wales, Australia.
  • Allied Health and Human Performance, University of South Australia, Adelaide, South Australia, Australia.

ORCID-Profile: Helen A Banwell, Peta E Tehan, Kristin Graham

Förderung

  • Allied Health and Human Performance Unit, University of South Australia

Zitieren

APA

Mazzeo, J., Banwell, H. A., Tehan, P. E., Anderson, G., & Graham, K. (2024). The use of a novel toe–thumb pressure index for assessing arterial status in the lower limb. A reliability and validity study. Journal of Foot and Ankle Research. https://doi.org/10.1002/jfa2.70011

Vancouver

Mazzeo J, Banwell HA, Tehan PE, Anderson G, Graham K. The use of a novel toe–thumb pressure index for assessing arterial status in the lower limb. A reliability and validity study. Journal of Foot and Ankle Research. 2024. doi:10.1002/jfa2.70011

BibTeX
@article{Mazzeo2024,
  author = {Mazzeo, Juliana and Banwell, Helen A and Tehan, Peta E and Anderson, Grace and Graham, Kristin},
  title = {The use of a novel toe–thumb pressure index for assessing arterial status in the lower limb. A reliability and validity study},
  journal = {Journal of Foot and Ankle Research},
  year = {2024},
  doi = {10.1002/jfa2.70011}
}
Kostenlos starten →