Beobachtungsstudie in der Zeitschrift The Journal of Knee Surgery, erschienen am 01.07.2024. Verfasst von Yoshikazu Sumida und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Chugoku Rosai Hospital, Hiroshima, Japan. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Range of Motion, Articular, Osteoarthritis, Knee, Knee Prosthesis. Die Arbeit nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We analyzed the intraoperative kinematics of total knee arthroplasty (TKA) using a navigation system to investigate the influence of different inserts on kinematics. This was a retrospective observational study. The Vanguard individualized design (33 patients, 33 knees) XP and anterior-stabilized (AS) inserts were used in TKA for osteoarthritis. Kinematic data were intraoperatively recorded. The range of motion, tibiofemoral rotational angle, anteroposterior translation of the femur, and varus-valgus laxity were compared between the two inserts (XP vs. AS). There was no significant difference in the range of motion (extension: XP, 3.7° ± 3.3° vs. AS, 3.8° ± 3.3°, p = 0.84; flexion: XP, 138.1° ± 10.2° vs. AS, 139.0° ± 13.3°, p = 0.73). With the AS insert, the tibia was gradually internally rotated as the knee was flexed. At maximum extension, the internal rotation was smallest with AS (XP 6.5° ± 4.0° vs. AS 5.1° ± 3.4°, p = 0.022), which was also associated with smaller anterior femoral translation (maximum extension: XP, 14.1 ± 4.8 mm vs. AS, 11.3 ± 4.7 mm, p = 0.00036; 30°: XP, 23.7 ± 5.6 mm vs. AS, 20.7 ± 5.1 mm, p = 0.000033; 45°: XP, 24.4 ± 4.9 mm vs. AS, 23.2 ± 4.5 mm, p = 0.0038). The AS was associated with a lower varus-valgus laxity (30° XP 4.1° ± 3.4 vs. AS 3.3° ± 2.7°, p = 0.036; 60°: XP, 3.2° ± 3.0° vs. AS, 2.4° ± 3.3°, p = 0.0089). The AS insert facilitated sequential tibiofemoral rotation with varus-valgus stability in mid-flexion without restricting the range of motion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRange of Motion, ArticularOsteoarthritis, KneeKnee ProsthesisPosterior Cruciate LigamentHumansRetrospective StudiesBiomechanical PhenomenaAgedFemaleMaleMiddle AgedKnee JointProsthesis DesignAged, 80 and over

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Chugoku Rosai Hospital, Hiroshima, Japan.

Zitieren

APA

Sumida, Y., Fujimoto, E., Masuda, Y., Ishibashi, S., & Sasashige, Y. (2024). Intraoperative Kinematics in Posterior Cruciate Ligament Retaining Total Knee Arthroplasty Using Different Inserts. The Journal of Knee Surgery, 37(09), 642-648. https://doi.org/10.1055/a-2240-3336

Vancouver

Sumida Y, Fujimoto E, Masuda Y, Ishibashi S, Sasashige Y. Intraoperative Kinematics in Posterior Cruciate Ligament Retaining Total Knee Arthroplasty Using Different Inserts. The Journal of Knee Surgery. 2024;37(09):642-648. doi:10.1055/a-2240-3336

BibTeX
@article{Sumida2024,
  author = {Sumida, Yoshikazu and Fujimoto, Eisaku and Masuda, Yasuji and Ishibashi, Saori and Sasashige, Yoshiaki},
  title = {Intraoperative Kinematics in Posterior Cruciate Ligament Retaining Total Knee Arthroplasty Using Different Inserts},
  journal = {The Journal of Knee Surgery},
  year = {2024},
  volume = {37},
  number = {09},
  pages = {642--648},
  doi = {10.1055/a-2240-3336}
}
Kostenlos starten →