Robotic Assisted TKA achieves adjusted mechanical alignment targets more consistently compared to manual TKA without improving outcomes
Journal of Experimental Orthopaedics · 2024-07 · 11 (3)
DOI: 10.1002/jeo2.70008 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Experimental Orthopaedics, online erschienen am 02.09.2024. Verfasst von Ashok Rajgopal und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Musculoskeletal Disorders and Orthopaedics Medanta-The Medicity Hospital Gurugram India. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Robotic total knee arthroplasty (rTKA), with its purported advantages of more accurate alignment, greater functional outcomes and patient satisfaction, is gaining popularity in patients undergoing TKA. The purpose of our study was to compare these parameters along with gait pattern and kneeling ability in a cohort of patients who underwent simultaneous TKA with manual instrumentation (mTKA) and rTKA in contralateral knees at a 1‐year follow‐up.
Methods
This was a retrospective review of 135 consecutive patients who underwent simultaneous bilateral TKA using robotic assistance on one side and manual instrumentation on the contralateral side between January 2022 and June 2022. The target alignment in both cohorts was adjusted mechanical. Patients were followed up at 3, 6 and 12 months to assess and compare alignment, range of motion (ROM) and patient‐reported outcome measures (PROM) data. Gait parameters and kneeling ability were assessed at 1‐year follow‐up.
Results
While adjusted mechanical alignment was achieved in all rTKA patients, we recorded five outliers (≥3° with relation to 180° HKA axis) in the mTKA cohort (three varus and two valgus). There were no significant differences between both cohorts with regards to ROM, PROM scores, gait analysis parameters and kneeling ability at 1‐year follow‐up. Conclusion rTKA helps in achieving the adjusted mechanical alignment more consistently than mTKA. This, however, does not contribute to better functional outcomes and patient satisfaction at 1‐year follow‐up. Level of Evidence Level III.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Musculoskeletal Disorders and Orthopaedics Medanta-The Medicity Hospital Gurugram India.
- Institute of Education and Research Medanta-The Medicity Hospital Gurugram India.
ORCID-Profile: Ashok Rajgopal
Zitieren
APA
Rajgopal, A., Sundararajan, S. S., Aggarwal, K., Kumar, S., & Singh, G. (2024). Robotic Assisted TKA achieves adjusted mechanical alignment targets more consistently compared to manual TKA without improving outcomes. Journal of Experimental Orthopaedics, 11(3). https://doi.org/10.1002/jeo2.70008
Vancouver
Rajgopal A, Sundararajan SS, Aggarwal K, Kumar S, Singh G. Robotic Assisted TKA achieves adjusted mechanical alignment targets more consistently compared to manual TKA without improving outcomes. Journal of Experimental Orthopaedics. 2024;11(3). doi:10.1002/jeo2.70008
BibTeX
@article{Rajgopal2024,
author = {Rajgopal, Ashok and Sundararajan, Sriram Surendra and Aggarwal, Kalpana and Kumar, Sumit and Singh, Gargi},
title = {Robotic Assisted TKA achieves adjusted mechanical alignment targets more consistently compared to manual TKA without improving outcomes},
journal = {Journal of Experimental Orthopaedics},
year = {2024},
volume = {11},
number = {3},
doi = {10.1002/jeo2.70008}
}
EUVIMED