EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Functional alignment in robotic‐assisted total knee arthroplasty for valgus deformity achieves safe coronal alignment and excellent short‐term outcomes

Pietro Gregori, Christos Koutserimpas, Vasileios Giovanoulis, Cécile Batailler, Elvire Servien, Sébastien Lustig

Knee Surgery, Sports Traumatology, Arthroscopy · 2025-06 · 33 (6) · 2187-2196

DOI: 10.1002/ksa.12585 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 17.01.2025. Verfasst von Pietro Gregori und 5 weiteren Autor:innen. Beteiligte Einrichtung: Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix Rousse Hospital, Hospices Civils de Lyon, Lyon North Un…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Knee Joint, Osteoarthritis, Knee. Die Arbeit wurde bisher 50-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: None.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Functional alignment (FA) in total knee arthroplasty (TKA) prioritizes soft tissue balancing and anatomical restoration without systematic correction to neutral alignment. Most studies have focused on varus deformity, with little evidence available about FA in valgus deformity. The hypothesis of the present study was that FA in robotic‐assisted TKA for valgus deformity would demonstrate correction of the coronal alignment and yield satisfactory short‐term outcomes.

Methods

This retrospective study included 58 patients with valgus coronal alignment (hip–knee–angle [HKA] ≥ 183°) who underwent robotic‐assisted TKA using the FA technique with a minimum of 1‐year follow‐up. Outcomes were assessed through the Knee Society Score (KSS), Oxford Knee Score (OKS), Forgotten Joint Score (FJS) and radiographic measurements of alignment and phenotypes. Complication and revision rates were also analyzed.

Results

The cohort included 39 females and 19 males with a median age of 70. Post‐operatively, 86.2% of cases achieved coronal alignment within the safe zone (HKA 177–183°). Significant improvements were observed in KSS (part 1: 69.5–95, part 2: 65–94, p < 0.001), while OKS and FJS exhibited optimal outcomes. Two complications were recorded: one aseptic loosening (1.7%) and one early infection (1.7%). Kaplan–Meier survival analysis indicated favourable implant survivorship at a median follow‐up of 18 months.

Conclusion

FA in image‐based robotic TKA is a safe and effective approach for patients with valgus deformity. This procedure resulted in a modest correction of the coronal alignment, where no soft tissue releases were needed. The majority of the cases fell within the target coronal alignment boundaries by only accommodating the individual laxities, suggesting the aim of FA to restore each knee's pre‐pathological alignment. Level of Evidence Level IV.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresKnee JointOsteoarthritis, KneeBone MalalignmentHumansMaleFemaleAgedRetrospective StudiesMiddle AgedTreatment OutcomeAged, 80 and over

Stichwörter der Autor:innen

functional alignmentknee phenotyperobotic knee replacementvalgus knee

Autor:innen und Institutionen

  • Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix Rousse Hospital, Hospices Civils de Lyon, Lyon North University Hospital, Lyon, France.
  • Fondazione Policlinico Universitario Campus Bio-Medico, Roma, Italy.
  • Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, Lyon, France.
  • LIBM-EA 7424, Interuniversity Laboratory of Biology of Mobility, Claude Bernard Lyon 1 University, Lyon, France.

Förderung

  • None

Zitieren

APA

Gregori, P., Koutserimpas, C., Giovanoulis, V., Batailler, C., Servien, E., & Lustig, S. (2025). Functional alignment in robotic‐assisted total knee arthroplasty for valgus deformity achieves safe coronal alignment and excellent short‐term outcomes. Knee Surgery, Sports Traumatology, Arthroscopy, 33(6), 2187-2196. https://doi.org/10.1002/ksa.12585

Vancouver

Gregori P, Koutserimpas C, Giovanoulis V, Batailler C, Servien E, Lustig S. Functional alignment in robotic‐assisted total knee arthroplasty for valgus deformity achieves safe coronal alignment and excellent short‐term outcomes. Knee Surgery, Sports Traumatology, Arthroscopy. 2025;33(6):2187-2196. doi:10.1002/ksa.12585

BibTeX
@article{Gregori2025,
  author = {Gregori, Pietro and Koutserimpas, Christos and Giovanoulis, Vasileios and Batailler, Cécile and Servien, Elvire and Lustig, Sébastien},
  title = {Functional alignment in robotic‐assisted total knee arthroplasty for valgus deformity achieves safe coronal alignment and excellent short‐term outcomes},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2025},
  volume = {33},
  number = {6},
  pages = {2187--2196},
  doi = {10.1002/ksa.12585}
}
Kostenlos starten →