EUVIMEDEUVIMED entdecken
Crossref

Physio‐Mechanic and Microscopic Analyses of Bioactive Glass‐Based Resin Infiltrants

Syed Zubairuddin Ahmed iD, Abdul Samad Khan, Wejdan Waleed Nasser, Methayel Abdulrahman Alrushaid, Zahrah Mohammed Alfaraj, Moayad Mohammed Aljeshi, Asma Tufail Shah, Budi Aslinie Md Sabri, Sultan Akhtar iD, Mohamed Ibrahim Abu Hassan

Microscopy Research and Technique · 2025

DOI: 10.1002/jemt.24725 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microscopy Research and Technique, 2025. Verfasst von Syed Zubairuddin Ahmed und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia. Hauptthemen laut MEDLINE: Glass, Ceramics, Composite Resins, Resins, Synthetic. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 58 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to investigate the efficacy and durability of bioactive glass‐based dental resin infiltrants. Resin infiltrants were formulated by combining photoinitiated dimethacrylate monomers with three variations of bioactive glass: 45S5 Bioglass (RIS), boron‐substituted (RIB), fluoride‐substituted (RIF), and pure resins (PR), whereby TOOTH group (TH) and ICON (CN) served as commercial control groups. Teeth samples were prepared, and experimental and control infiltrants were applied on demineralized human‐extracted teeth. All the samples were subjected to immersion in artificial saliva and pH cycling for 30 days. The samples from another group underwent tooth brushing simulation for 9600 cycles. Following artificial saliva immersion, the samples' hardness values showed that RIB had the highest values (318.44 ± 3.83) while PR (212.52 ± 9.02) had the lowest values. After immersing into the pH cycling solution, the RIF showed the highest hardness (286.86 ± 5.11), while the lowest values for the CN (143.76 ± 3.50). After the tooth brushing simulation, the teeth samples with RIB showed maximum microhardness values (312.06 ± 16.30) and the weakest for the TH (189.60 ± 6.43). The commercial and experimental enamel resin infiltrants showed almost similar results overall, with RIB demonstrating better microhardness and comparable surface roughness. In contrast, RIF proved more resistant to pH cycling, exhibited higher microhardness, and performed better in surface roughness analysis. These findings suggest that resin infiltrant materials, especially RIF, have promising potential for effectively and esthetically managing white spot lesions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GlassCeramicsComposite ResinsResins, SyntheticHumansHardnessMaterials TestingHydrogen-Ion ConcentrationSurface PropertiesToothSaliva, Artificial

Stichwörter der Autor:innen

ICONVickers microhardnessartificial salivaexperimental resin infiltrantsmorphological analysispH cyclingsurface roughnesstooth brushing simulator

Substanzen

bioactive glass 45S5Composite ResinsSaliva, ArtificialResins, Synthetic

Autor:innen und Institutionen

  • Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia.
  • College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia.
  • Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad, Lahore, Pakistan.
  • College of Dentistry, Universiti Teknologi MARA (UiTM), Shah Alam, Sungai Buloh, Selangor, Malaysia.
  • Department of Biophysics, Institute for Research and Medical Consultations, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia.
  • College of Dentistry, MAHSA University, Jenjarom, Selangor, Malaysia.

ORCID-Profile: Syed Zubairuddin Ahmed, Sultan Akhtar

Zitieren

APA

Ahmed, S. Z., Khan, A. S., Nasser, W. W., Alrushaid, M. A., Alfaraj, Z. M., Aljeshi, M. M., Shah, A. T., Sabri, B. A. M., Akhtar, S., & Hassan, M. I. A. (2025). Physio‐Mechanic and Microscopic Analyses of Bioactive Glass‐Based Resin Infiltrants. Microscopy Research and Technique. https://doi.org/10.1002/jemt.24725

Vancouver

Ahmed SZ, Khan AS, Nasser WW, Alrushaid MA, Alfaraj ZM, Aljeshi MM, et al. Physio‐Mechanic and Microscopic Analyses of Bioactive Glass‐Based Resin Infiltrants. Microscopy Research and Technique. 2025. doi:10.1002/jemt.24725

BibTeX
@article{Ahmed2025,
  author = {Ahmed, Syed Zubairuddin and Khan, Abdul Samad and Nasser, Wejdan Waleed and Alrushaid, Methayel Abdulrahman and Alfaraj, Zahrah Mohammed and Aljeshi, Moayad Mohammed and Shah, Asma Tufail and Sabri, Budi Aslinie Md and Akhtar, Sultan and Hassan, Mohamed Ibrahim Abu},
  title = {Physio‐Mechanic and Microscopic Analyses of Bioactive Glass‐Based Resin Infiltrants},
  journal = {Microscopy Research and Technique},
  year = {2025},
  doi = {10.1002/jemt.24725}
}
Kostenlos starten →