EUVIMEDEUVIMED entdecken
Vergleichsstudie

Optical coherence tomography and gray scale digital analysis as noninvasive techniques for evaluating molar‐incisor hypomineralization severity: A comparative study with microcomputed tomography

Maria Livia Rodrigues de Oliveira, Ayla Natalia Ferezin, Bianca Caroline Gomes, Vicente Silva Mattos, Jardel Francisco Mazzi-Chaves iD, Manoel Damião Sousa-Neto iD, Alexandra Mussolino de Queiroz iD, Francisco Wanderley Garcia de Paula-Silva iD, Fabrício Kitazono de Carvalho iD

Microscopy Research and Technique · 2024

DOI: 10.1002/jemt.24558 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Microscopy Research and Technique, 2024. Verfasst von Maria Livia Rodrigues de Oliveira und 8 weiteren Autor:innen. Beteiligte Einrichtung: Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto, Brazil. Hauptthemen laut MEDLINE: X-Ray Microtomography, Tomography, Optical Coherence, Dental Enamel Hypoplasia, Dental Enamel. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: National Council for Scientific and Technological Development (CNPq), Conselho Nacional de Desenvolvimento Científico e Tecnológico.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Molar‐incisor hypomineralization (MIH) is a qualitative defect of dental enamel characterized by demarcated opacities present in permanent first molars and other teeth. It is considered a major clinical challenge in dentistry because it makes affected teeth more susceptible to fractures and dental caries. Its diagnosis is mainly clinical and there are few technological resources that allow for a more accurate diagnosis, especially with respect to the depth of the defect in the dental enamel. In this context, optical coherence tomography (OCT), which is routinely used in ophthalmology, can produce images of the depth of the dental enamel, making it a promising method. In this study, 33 teeth with different MIH severities were evaluated using OCT and microcomputed tomography (microCT). Semi‐quantitative methods of grayscale pattern analysis were used to compare images obtained from different severities of MIH with the mineral density obtained through microCT. MicroCT evaluation revealed that hypomineralized enamel had a significantly lower mineral density than intact enamel. However, this difference was not observed between the mild and severe MIH lesions. In the OCT evaluation, significant differences were observed between the intact and hypomineralized enamel, and the gray value comparison provided a method for quantitative differentiation between the two. This study suggests that OCT could be a useful adjunct to traditional diagnostic methods for MIH, offering a noninvasive approach to evaluate enamel defects. Research Highlights Combining optical coherence tomography with grayscale digital analysis shows potential as a promising method for diagnosing molar‐incisor hypomineralization and assessing its level of severity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

X-Ray MicrotomographyTomography, Optical CoherenceDental Enamel HypoplasiaDental EnamelHumansMolarFemaleChildMaleAdolescentIncisorMolar Hypomineralization

Stichwörter der Autor:innen

OCTenamelhypomineralizationmicroCT

Autor:innen und Institutionen

  • Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto, Brazil.
  • São Carlos Institute of Physics, University of São Paulo, São Paulo, Brazil.

ORCID-Profile: Jardel Francisco Mazzi-Chaves, Manoel Damião Sousa-Neto, Alexandra Mussolino de Queiroz, Francisco Wanderley Garcia de Paula-Silva, Fabrício Kitazono de Carvalho

Förderung

  • National Council for Scientific and Technological Development (CNPq)
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico

Zitieren

APA

de Oliveira, M. L. R., Ferezin, A. N., Gomes, B. C., Mattos, V. S., Mazzi-Chaves, J. F., Sousa-Neto, M. D., de Queiroz, A. M., de Paula-Silva, F. W. G., & de Carvalho, F. K. (2024). Optical coherence tomography and gray scale digital analysis as noninvasive techniques for evaluating molar‐incisor hypomineralization severity: A comparative study with microcomputed tomography. Microscopy Research and Technique. https://doi.org/10.1002/jemt.24558

Vancouver

de Oliveira MLR, Ferezin AN, Gomes BC, Mattos VS, Mazzi-Chaves JF, Sousa-Neto MD, et al. Optical coherence tomography and gray scale digital analysis as noninvasive techniques for evaluating molar‐incisor hypomineralization severity: A comparative study with microcomputed tomography. Microscopy Research and Technique. 2024. doi:10.1002/jemt.24558

BibTeX
@article{deOliveira2024,
  author = {de Oliveira, Maria Livia Rodrigues and Ferezin, Ayla Natalia and Gomes, Bianca Caroline and Mattos, Vicente Silva and Mazzi-Chaves, Jardel Francisco and Sousa-Neto, Manoel Damião and de Queiroz, Alexandra Mussolino and de Paula-Silva, Francisco Wanderley Garcia and de Carvalho, Fabrício Kitazono},
  title = {Optical coherence tomography and gray scale digital analysis as noninvasive techniques for evaluating molar‐incisor hypomineralization severity: A comparative study with microcomputed tomography},
  journal = {Microscopy Research and Technique},
  year = {2024},
  doi = {10.1002/jemt.24558}
}
Kostenlos starten →