Diagnostic accuracy of Point Of Care UltraSound ( POCUS ) in clinical practice: A retrospective, emergency department based study
Journal of Clinical Ultrasound · 2024
DOI: 10.1002/jcu.23619 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Ultrasound, 2024. Verfasst von Michele Domenico Spampinato und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Translational Medicine, University of Ferrara, Ferrara, Italy. Hauptthemen laut MEDLINE: Point-of-Care Systems, Point-of-Care Testing. Die Arbeit wurde bisher 38-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: University of Ferrara, Italian Ministry of Public Health, Università degli Studi di Ferrara.
Abstract (Originalsprache)
Aims
Point‐of‐care ultrasound (POCUS) is the acquisition and interpretation of ultrasound imaging at the bedside to solve specific clinical questions based on signs and symptoms of presentation. While several studies evaluated POCUS diagnostic accuracy for a variety of clinical pictures in the emergency department (ED), only a few data are available on POCUS diagnostic accuracy performed by physicians with different POCUS skills. The objective of this research was to evaluate the diagnostic accuracy of POCUS compared to standard diagnostic imaging in the ED. Materials and Methods This was a retrospective study conducted in the ED of a third‐level university hospital. Patients who underwent cardiac, thoracic, abdominal, or venous lower limb POCUS and a standard imaging examination between June 2021 and January 2022 were included.
Results
1047 patients were screened, and 844 patients included. A total of 933 POCUS was included (102, 12.09%, cardiac; 466, 55.21%, thoracic; 336, 39.8%, abdominal; 29, 3.44%, lower limb venous POCUS), accounting for 2029 examinations. POCUS demonstrated 96.6% (95% CI 95.72–97.34) accuracy, 47.73 (95% CI 33.64–67.72) +LR, 0.09 (95% CI 0.06–0.12) −LR. +LR was greater than 10 for all investigations but for hydronephrosis (5.8), and −LR never exceeded 0.4.
Conclusions
POCUS exhibited high diagnostic accuracy for virtually all conditions when performed by emergency department physicians.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Translational Medicine, University of Ferrara, Ferrara, Italy.
- School of Emergency Medicine, University of Ferrara, Ferrara, Italy.
- Emergency Department, Maggiore Hospital, AUSL di Bologna, Bologna, Italy.
ORCID-Profile: Michele Domenico Spampinato, Francesco Luppi
Förderung
- University of Ferrara
- Italian Ministry of Public Health
- Università degli Studi di Ferrara
Zitieren
APA
Spampinato, M. D., Luppi, F., Cristofaro, E., Benedetto, M., Cianci, A., Bachechi, T., Ghirardi, C., Perna, B., Guarino, M., Passaro, A., De Giorgio, R., & Sofia, S. (2024). Diagnostic accuracy of Point Of Care UltraSound ( POCUS ) in clinical practice: A retrospective, emergency department based study. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.23619
Vancouver
Spampinato MD, Luppi F, Cristofaro E, Benedetto M, Cianci A, Bachechi T, et al. Diagnostic accuracy of Point Of Care UltraSound ( POCUS ) in clinical practice: A retrospective, emergency department based study. Journal of Clinical Ultrasound. 2024. doi:10.1002/jcu.23619
BibTeX
@article{Spampinato2024,
author = {Spampinato, Michele Domenico and Luppi, Francesco and Cristofaro, Enrico and Benedetto, Marcello and Cianci, Antonella and Bachechi, Tommaso and Ghirardi, Caterina and Perna, Benedetta and Guarino, Matteo and Passaro, Angelina and De Giorgio, Roberto and Sofia, Soccorsa},
title = {Diagnostic accuracy of Point Of Care UltraSound ( POCUS ) in clinical practice: A retrospective, emergency department based study},
journal = {Journal of Clinical Ultrasound},
year = {2024},
doi = {10.1002/jcu.23619}
}
EUVIMED