EUVIMEDEuropean Health Evidence
Uhr 7/7Sources Journal Tree
Easy Demo

Lokaler Crossref-Datenbestand · journal-article

Establishment Reference Intervals Using the Kosmic Algorithm for Hemoglobin Levels and Platelet, Red Blood Cell, and White Blood Cell Counts

Chunyan Liu, Zhaohui Deng, Yingbo Song, Wenli Wu, Yan Li, Fang Yang, Huimin Liu, Xin Zhang

Journal of Clinical Laboratory Analysis · 2026

Vollständiger Abstract

Worum geht es in dieser Arbeit?

ABSTRACT Introduction Reference intervals ( RIs ) for complete blood count ( CBC ) are crucial for assessment of overall health status and effective diagnosis of diseases. However, the RI data for CBC currently used in clinical practice in China are mainly derived from the Han Chinese population and are not stratified by ethnicity. This study aimed to calculate RIs for red blood cell count ( RBC ), hemoglobin ( HGB ), white blood cell count ( WBC ), and platelet count ( PLT ) among local populations based on ethnicity and sex in Xinjiang, China, using an indirect method to help clinicians better explain patient status in multiethnic populations. Methods We analyzed data from 5679 individuals. We used Tukey's test to eliminate outliers based on ethnicity, sex, and age. Subgroup stratification of RIs for RBC, WBC, PLT, and HGB was determined according to a standard deviation ratio threshold. Total RIs and ethnicity‐ and sex‐specific RIs for these parameters were calculated using the kosmic algorithm. Results The RIs for RBC and HGB must be stratified by sex, while those for PLT must be stratified by ethnicity. However, the RI for WBC does not require stratification. Sex‐stratified RIs for RBC and HGB in men showed higher upper limits than those in women. The RI for Uyghur individuals had a higher upper limit than that for Han Chinese individuals. Conclusions Personalized RIs for CBC provide a laboratory basis for disease diagnosis and treatment and health assessment among adults in Xinjiang.

Bibliografischer Nachweis

Publikationsdaten

Autor:innen
Chunyan Liu, Zhaohui Deng, Yingbo Song, Wenli Wu, Yan Li, Fang Yang, Huimin Liu, Xin Zhang
Quelle
Journal of Clinical Laboratory Analysis
Publikation
2026-01-01
Band / Ausgabe
Nicht angegeben
Seiten
Nicht angegeben
ISSN / ISBN
0887-8013, 1098-2825
Zitationen
0 laut Crossref
Referenzen
0 hinterlegt

Zitieren

Zitierfähiger Nachweis

Chunyan Liu, Zhaohui Deng, Yingbo Song, Wenli Wu, Yan Li, Fang Yang, Huimin Liu, Xin Zhang (2026). Establishment Reference Intervals Using the Kosmic Algorithm for Hemoglobin Levels and Platelet, Red Blood Cell, and White Blood Cell Counts. Journal of Clinical Laboratory Analysis. https://doi.org/10.1002/jcla.70341
RIS BibTeX CSL-JSON

Kontext

Themen, Förderung und Nutzung

Lizenzhinweise: Lizenz 1 · Lizenz 2