EUVIMEDEUVIMED entdecken
Crossref

Finite Element Analysis of Conventional Fixation and 3D ‐Printed Scaffold Integration for Treating Large Osseous Femoral Defects

Panagiotis Ntakos iD, Christos Kalligeros, Konstantinos Chouzouris, Vasilios Gakos, Athanasios F Foukas, Athanasios Armakolas, Olga D Savvidou iD, Panayiotis J Papagelopoulos, Vasilios Spitas

Journal of Biomedical Materials Research Part B: Applied Biomaterials · 2025

DOI: 10.1002/jbmb.70010 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2025. Verfasst von Panagiotis Ntakos und 8 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Machine Design, National Technical University of Athens, Zografou, Greece. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Finite Element Analysis, Tissue Scaffolds, Femur. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 67 Literaturangaben. Gefördert von: European Union (NextGenerationEU), Greece 2.0, NextGenerationEU.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigated the biomechanical efficacy of conventional and 3D‐printed scaffold‐augmented fixation methods for a large 6 cm osseous femoral defect. Finite element analyses were conducted to compare four conventional techniques: single plate, intramedullary nail, combined plate and nail, and double plate. These were then evaluated with the addition of three porous Ti‐6Al‐4V scaffold designs (Weaire–Phelan, Diamond, and Voronoi) with 70% porosity. Models were subjected to peak physiological loading from gait, simulating a 106 kg patient. Performance was assessed based on implant stress and the volume fraction of the fracture callus experiencing osteogenic strains (0.005%–2.5%). Results showed that conventional single‐implant methods were mechanically insufficient; the single plate failed at 20% of the physiological load and the nail at 90%. These methods also produced suboptimal osteogenic environments, with an osteogenic volume fraction < 16%. In contrast, combined conventional methods (plate and nail, double plate) withstood 100% of the load with significantly lower stresses and promoted highly osteogenic environments, with an osteogenic volume fraction > 95%. The integration of 3D‐printed scaffolds transformed the single‐implant constructs, enabling them to withstand 100% physiological load and increasing their osteogenic volume fraction to over 90%. Scaffolds also substantially reduced stress on the primary implants in all configurations. The plate and nail fixation augmented with a scaffold emerged as the most robust strategy, reducing conventional implant stresses to approximately 140 MPa while maintaining an exceptional osteogenic volume fraction > 99%. These findings highlight the quantitative potential of 3D‐printed scaffolds to improve treatment outcomes for large bone defects.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalFinite Element AnalysisTissue ScaffoldsFemurFemoral FracturesBone PlatesHumansTitaniumAlloysBone Nails

Stichwörter der Autor:innen

3D‐printed scaffoldsbone defectfinite element analysisosteogenesisosteointegrationunit cell

Substanzen

titanium alloy (TiAl6V4)TitaniumAlloys

Autor:innen und Institutionen

  • Laboratory of Machine Design, National Technical University of Athens, Zografou, Greece.
  • Third Department of Orthopaedic Surgery, "KAT" General Hospital of Athens, Kifissia, Greece.
  • Department of Experimental Physiology, Medical School, National and Kapodistrian University of Athens, Athens, Greece.
  • First Department of Orthopaedic Surgery, National and Kapodistrian University of Athens, Faculty of Medicine, Attikon University Hospital, Athens, Greece.

ORCID-Profile: Panagiotis Ntakos, Olga D Savvidou

Förderung

  • European Union (NextGenerationEU), Greece 2.0
  • NextGenerationEU

Zitieren

APA

Ntakos, P., Kalligeros, C., Chouzouris, K., Gakos, V., Foukas, A. F., Armakolas, A., Savvidou, O. D., Papagelopoulos, P. J., & Spitas, V. (2025). Finite Element Analysis of Conventional Fixation and 3D ‐Printed Scaffold Integration for Treating Large Osseous Femoral Defects. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbmb.70010

Vancouver

Ntakos P, Kalligeros C, Chouzouris K, Gakos V, Foukas AF, Armakolas A, et al. Finite Element Analysis of Conventional Fixation and 3D ‐Printed Scaffold Integration for Treating Large Osseous Femoral Defects. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 2025. doi:10.1002/jbmb.70010

BibTeX
@article{Ntakos2025,
  author = {Ntakos, Panagiotis and Kalligeros, Christos and Chouzouris, Konstantinos and Gakos, Vasilios and Foukas, Athanasios F and Armakolas, Athanasios and Savvidou, Olga D and Papagelopoulos, Panayiotis J and Spitas, Vasilios},
  title = {Finite Element Analysis of Conventional Fixation and 3D ‐Printed Scaffold Integration for Treating Large Osseous Femoral Defects},
  journal = {Journal of Biomedical Materials Research Part B: Applied Biomaterials},
  year = {2025},
  doi = {10.1002/jbmb.70010}
}
Kostenlos starten →