Flexure-Based Locking Plates Can Modulate Interfragmentary Motion in Distal Femur and Diaphyseal Fractures: A Parametric Finite Element Analysis
Journal of Biomechanical Engineering · 2026
DOI: 10.1115/1.4070406 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2026. Verfasst von Connor Huxman und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Penn State University, University Park, PA 16802. Hauptthemen laut MEDLINE: Finite Element Analysis, Bone Plates, Femoral Fractures, Diaphyses. Die Arbeit nennt 68 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS.
Abstract (Originalsprache)
Axial interfragmentary motion is known to stimulate fracture healing. A mechanically compliant fracture fixation plate incorporating flexures is proposed to provide controlled axial micromotion to long bone fractures. To explore the concept's feasibility, computational modeling of general diaphyseal and distal femur fractures treated with both rigid and compliant plates is conducted. In Part I of this study, a diaphyseal fracture finite element model for novel compliant plates is validated against experimental data with good agreement. In Part II, a parametric analysis is conducted using the validated model to characterize the performance of many compliant plate designs with varying geometry and materials. Under axial loading, all compliant plate configurations provided greater (1.03 mm versus 0.22 mm) and more symmetric (270–390%) axial interfragmentary motion than rigid plates. Steel compliant plates with thicker flexures (0.3–0.6 mm) may provide the best performance given their enhanced motion and comparable bending/torsional rigidity. In Part III, compliant plates are adapted for use in treating distal femur fractures. Results demonstrate that compared to a rigid plate, a compliant distal femur plate with increased thickness can effectively modulate interfragmentary motion—that is, increase the insufficient near cortex motion under low loads (from 0.14 mm to 0.23 mm) and reduce the excessive far cortex motion under large loads (from 7.96 mm to 2.54 mm). Flexure-based locking plates represent a promising new approach to treating diaphyseal and/or distal femur fractures. Additional research is needed to investigate in vivo performance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, Penn State University, University Park, PA 16802.
- Pennsylvania State University.
- Department of Orthopaedics and Rehabilitation, Penn State College of Medicine, Hershey, PA 17033.
- School of Engineering Design and Innovation, Penn State University, University Park, PA 16802.
Förderung
- NIBIB NIH HHS
Zitieren
APA
Huxman, C., Updegrove, G., Armstrong, A., Wee, H., Frecker, M. I., Butler, J., & Lewis, G. S. (2026). Flexure-Based Locking Plates Can Modulate Interfragmentary Motion in Distal Femur and Diaphyseal Fractures: A Parametric Finite Element Analysis. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4070406
Vancouver
Huxman C, Updegrove G, Armstrong A, Wee H, Frecker MI, Butler J, et al. Flexure-Based Locking Plates Can Modulate Interfragmentary Motion in Distal Femur and Diaphyseal Fractures: A Parametric Finite Element Analysis. Journal of Biomechanical Engineering. 2026. doi:10.1115/1.4070406
BibTeX
@article{Huxman2026,
author = {Huxman, Connor and Updegrove, Gary and Armstrong, April and Wee, Hwabok and Frecker, Mary I and Butler, Jared and Lewis, Gregory S},
title = {Flexure-Based Locking Plates Can Modulate Interfragmentary Motion in Distal Femur and Diaphyseal Fractures: A Parametric Finite Element Analysis},
journal = {Journal of Biomechanical Engineering},
year = {2026},
doi = {10.1115/1.4070406}
}
EUVIMED