Apatite Nuclei Treatment of Three‐Dimensional Printed Porous Carbon‐Reinforced Polyetheretherketone: A Case Study of Rat Femoral Segmental Defect
Journal of Biomedical Materials Research Part B: Applied Biomaterials · 2026-06 · 114 (6)
DOI: 10.1002/jbm.b.70116 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomedical Materials Research Part B: Applied Biomaterials, online erschienen am 15.06.2026. Verfasst von Masaki Sakamoto und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan. Hauptthemen laut MEDLINE: Ketones, Polyethylene Glycols, Femur, Printing, Three-Dimensional. Die Arbeit nennt 23 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
Polyetheretherketone (PEEK) is a promising orthopedic implant material with an elastic modulus similar to that of human bone, offering potential advantages over titanium implants. However, PEEK is inherently biologically inert and hydrophobic, limiting its bone‐bonding capacity. This study investigated the efficacy of apatite nuclei (AN) treatment in enhancing the bioactivity of 3D‐printed porous carbon‐reinforced PEEK (CR‐PEEK) implants. Scanning electron microscopy coupled with energy‐dispersive X‐ray spectroscopy analysis confirmed uniform AN treatment penetration throughout the porous structure, with a calcium peak detected both on the surfaces and in the interior regions. Forty‐eight male Sprague–Dawley rats, divided into four groups, received segmental femoral defect implants based on structure (porous vs. dense) and AN treatment (with vs. without); the AN treatment effects were evaluated within each structural type. At 8 weeks, Micro computed tomography analysis demonstrated a significant enhancement in bone formation in AN‐treated groups for both porous ( p = 0.003) and dense ( p = 0.004) implants. Histological evaluation revealed that AN treatment promoted bone ingrowth from 4.50% to 25.10% in porous implants ( p = 0.006) and improved bone‐implant contact from 2.94% to 9.33% in dense implants ( p = 0.008). These findings demonstrate that AN treatment enhances osseointegration in CR‐PEEK implants regardless of implant structure, and confirm for the first time that AN treatment effectively penetrates complex 3D porous geometries. The combination of 3D‐printed porous architecture and AN treatment offers a technically feasible strategy for developing bioactive CR‐PEEK implants, with the increased surface area of porous structures potentially augmenting the effects of AN treatment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan.
- Department of Fundamental Energy Science, Graduate School of Energy Science, Kyoto University, Kyoto, Japan.
ORCID-Profile: Takayoshi Shimizu, Toshiyuki Kawai
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Sakamoto, M., Shimizu, T., Yabutsuka, T., Naka, S., Yoshinaga, K., Otsuki, B., Kawai, T., Okuzu, Y., Takaoka, Y., & Matsuda, S. (2026). Apatite Nuclei Treatment of Three‐Dimensional Printed Porous Carbon‐Reinforced Polyetheretherketone: A Case Study of Rat Femoral Segmental Defect. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 114(6). https://doi.org/10.1002/jbm.b.70116
Vancouver
Sakamoto M, Shimizu T, Yabutsuka T, Naka S, Yoshinaga K, Otsuki B, et al. Apatite Nuclei Treatment of Three‐Dimensional Printed Porous Carbon‐Reinforced Polyetheretherketone: A Case Study of Rat Femoral Segmental Defect. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 2026;114(6). doi:10.1002/jbm.b.70116
BibTeX
@article{Sakamoto2026,
author = {Sakamoto, Masaki and Shimizu, Takayoshi and Yabutsuka, Takeshi and Naka, Soichiro and Yoshinaga, Kurumi and Otsuki, Bungo and Kawai, Toshiyuki and Okuzu, Yaichiro and Takaoka, Yusuke and Matsuda, Shuichi},
title = {Apatite Nuclei Treatment of Three‐Dimensional Printed Porous Carbon‐Reinforced Polyetheretherketone: A Case Study of Rat Femoral Segmental Defect},
journal = {Journal of Biomedical Materials Research Part B: Applied Biomaterials},
year = {2026},
volume = {114},
number = {6},
doi = {10.1002/jbm.b.70116}
}
EUVIMED