EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Degradation and Fatigue Behavior of 3D ‐Printed Bioresorbable Tracheal Splints

Jenna M Wahbeh iD, John Lama, Sang-Hyun Park, Edward Ebramzadeh, Scott J Hollister, Sophia N Sangiorgio

Journal of Biomedical Materials Research Part B: Applied Biomaterials · 2024

DOI: 10.1002/jbm.b.35501 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2024. Verfasst von Jenna M Wahbeh und 5 weiteren Autor:innen. Beteiligte Einrichtung: J. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Luskin Orthopaedic Institute for Children in Alliance With UCLA, Los Angeles, California, USA. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Absorbable Implants, Trachea, Materials Testing. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NICHD NIH HHS, NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Severe infantile tracheobronchomalacia (TBM) is often treated with invasive surgery and fixed‐size implants to support the trachea during respiration. A novel 3D‐printed extra‐luminal splint has been developed as a flexible and bioresorbable alternative. Therefore, the goal of the present study was to use an in vitro breathing simulator model to comprehensively evaluate the structural stiffness and failure modes of two sizes of a novel bioresorbable 3D‐printed splint design under a range of physiological degradation conditions. Two thicknesses, 2 mm and 3 mm, of a novel 3D‐printed bioresorbable splint were evaluated under two different degradation conditions, phosphate‐buffered saline (PBS) and sodium hydroxide (NaOH). The splints were subjected to simulated breathing loading, involving a cyclic opening and closing of the splint by 2 mm, for a targeted duration of 7.5 to 30 million cycles. A separate new set of splints were statically soaked in their respective degradation condition for a comparative analysis of the effects of cyclic loading by the degradation medium. After successfully simulated breathing or static soaking, non‐destructive tensile and compressive strengths were evaluated, and overall stiffness was calculated from destructive tensile testing. The present study indicates that the splints were more significantly degraded under simulated breathing conditions than under soaking. Cyclic simulated breathing specimens failed far earlier than the intended duration of loading. Over time, both 2 mm and 3 mm splints became increasingly more flexible when subjected to the static degradation conditions. Interestingly, there was little difference in the compressive and tensile strengths of the 2 mm and 3 mm thickness splints. The bioresorbable nature of PCL offers a valuable advantage as it eliminates the need for splint removal surgery and increases device flexibility over time with degradation. This increased flexibility is crucial because it allows for uninhibited growth and development of the infant's trachea over the intended use period of 2 years. The results of this study confirm that the splints were able to withstand tensile forces to prevent tracheal collapse. This study further supports the successful use of 3D‐printed splints in the treatment of infantile TBM.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalAbsorbable ImplantsTracheaMaterials TestingSplintsHumans

Stichwörter der Autor:innen

3D‐printingTracheobronchomalaciadegradationfatiguesplint

Autor:innen und Institutionen

  • J. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Luskin Orthopaedic Institute for Children in Alliance With UCLA, Los Angeles, California, USA.
  • Department of Bioengineering, University of California, Los Angeles, California, USA.
  • Department of Orthopaedic Surgery, University of California, Los Angeles, California, USA.
  • Department of Biomedical Engineering, Georgia Institute for Technology, Atlanta, California, USA.

ORCID-Profile: Jenna M Wahbeh

Förderung

  • NICHD NIH HHS
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Wahbeh, J. M., Lama, J., Park, S. H., Ebramzadeh, E., Hollister, S. J., & Sangiorgio, S. N. (2024). Degradation and Fatigue Behavior of 3D ‐Printed Bioresorbable Tracheal Splints. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.35501

Vancouver

Wahbeh JM, Lama J, Park SH, Ebramzadeh E, Hollister SJ, Sangiorgio SN. Degradation and Fatigue Behavior of 3D ‐Printed Bioresorbable Tracheal Splints. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 2024. doi:10.1002/jbm.b.35501

BibTeX
@article{Wahbeh2024,
  author = {Wahbeh, Jenna M and Lama, John and Park, Sang-Hyun and Ebramzadeh, Edward and Hollister, Scott J and Sangiorgio, Sophia N},
  title = {Degradation and Fatigue Behavior of 3D ‐Printed Bioresorbable Tracheal Splints},
  journal = {Journal of Biomedical Materials Research Part B: Applied Biomaterials},
  year = {2024},
  doi = {10.1002/jbm.b.35501}
}
Kostenlos starten →