EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessing Effects of Riboflavin/ UV ‐A Cross‐Linking on Aqueous Outflow Facility, Corneal Biomechanics and Their Association With Intraocular Pressure

Yilong Zhang, Zhengshuyi Feng, Xingyu Jiang, Robert Scott, Ying Yang, Chunhui Li iD, Zhihong Huang

Journal of Biophotonics · 2026

DOI: 10.1002/jbio.202500432 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biophotonics, 2026. Verfasst von Yilong Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Physics, Engineering and Technology, University of York, York, UK. Hauptthemen laut MEDLINE: Riboflavin, Intraocular Pressure, Cornea, Ultraviolet Rays. Die Arbeit nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Riboflavin/UV‐A corneal collagen cross‐linking (CXL) is a standard treatment for early‐stage keratoconus. However, quantitative CXL outcomes remain limited. This study evaluated CXL effects on outflow facility and corneal biomechanics at intraocular pressures (IOPs) in ex vivo porcine eyes. Ocular rigidity and outflow facility were derived from pressure–volume and IOP decay curves using a direct manometric technique, while corneal elasticity (Young's modulus) was measured via non‐contact air‐pulse optical coherence elastography. CXL increased ocular rigidity (0.0066 ± 0.0001 μL −1 vs. 0.0060 ± 0.0002 μL −1 ) and reduced outflow facility from 0.5429 ± 0.0320 to 0.1485 ± 0.0153 μL/min/mmHg (20–40 mmHg), compared to 0.7327 ± 0.0894–0.2210 ± 0.0502 μL/min/mmHg in untreated eyes. Young's modulus increased by 92%, 89%, and 155% at 20, 30, and 40 mmHg. These findings enhance our understanding of flow dynamics at IOP levels, suggesting that outflow facility and corneal biomechanics may serve as potential indicators for evaluating the effectiveness of CXL.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RiboflavinIntraocular PressureCorneaUltraviolet RaysCross-Linking ReagentsAqueous HumorAnimalsBiomechanical PhenomenaSwineCollagen

Stichwörter der Autor:innen

air‐pulse optical coherence elastographybiomechanical propertiesintraocular pressurekeratoconusmanometric measurementoutflow facilityriboflavin/UV‐A corneal collagen cross‐linking

Substanzen

RiboflavinCross-Linking ReagentsCollagen

Autor:innen und Institutionen

  • School of Physics, Engineering and Technology, University of York, York, UK.
  • Centre for Medical Engineering and Technology, School of Science and Engineering, University of Dundee, Dundee, UK.
  • Théa Pharmaceuticals Ltd, Keele, UK.
  • School of Pharmacy and Bioengineering, Keele University, Stoke-on-Trent, UK.

ORCID-Profile: Chunhui Li

Zitieren

APA

Zhang, Y., Feng, Z., Jiang, X., Scott, R., Yang, Y., Li, C., & Huang, Z. (2026). Assessing Effects of Riboflavin/ UV ‐A Cross‐Linking on Aqueous Outflow Facility, Corneal Biomechanics and Their Association With Intraocular Pressure. Journal of Biophotonics. https://doi.org/10.1002/jbio.202500432

Vancouver

Zhang Y, Feng Z, Jiang X, Scott R, Yang Y, Li C, et al. Assessing Effects of Riboflavin/ UV ‐A Cross‐Linking on Aqueous Outflow Facility, Corneal Biomechanics and Their Association With Intraocular Pressure. Journal of Biophotonics. 2026. doi:10.1002/jbio.202500432

BibTeX
@article{Zhang2026,
  author = {Zhang, Yilong and Feng, Zhengshuyi and Jiang, Xingyu and Scott, Robert and Yang, Ying and Li, Chunhui and Huang, Zhihong},
  title = {Assessing Effects of Riboflavin/ UV ‐A Cross‐Linking on Aqueous Outflow Facility, Corneal Biomechanics and Their Association With Intraocular Pressure},
  journal = {Journal of Biophotonics},
  year = {2026},
  doi = {10.1002/jbio.202500432}
}
Kostenlos starten →