EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Long-Term Corneal Reshaping Using Riboflavin–UVA Crosslinking Combined With Decorin in Rabbits

Chenli Feng, Xueqi Lin, Jiayue Yuan, Lingyan Wang, Lin Ye, Qianhong Feng, Shichu Liu, Zheng Li, Fei Yuan, Jinhui Dai

Translational Vision Science & Technology · 2025

DOI: 10.1167/tvst.14.10.24 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational Vision Science & Technology, 2025. Verfasst von Chenli Feng und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Zhongshan Hospital, Fudan University, Shanghai, China. Hauptthemen laut MEDLINE: Riboflavin, Decorin, Cross-Linking Reagents, Cornea. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To establish a preclinical proof of concept for a novel, non-ablative method for long-term corneal reshaping and to investigate its biomechanical and safety profiles.

Methods

A rabbit model of non-ablative corneal reshaping was established using a custom molding device. The optimal protocol involved stromal reshaping stabilized by riboflavin-ultraviolet A (UVA) collagen cross-linking (CXL; 7.2 J/cm2), with topical decorin applied as a biological modulator to maintain corneal clarity. Corneal topography was monitored for 12 months. Safety was assessed via in vivo clinical examinations, histology, and electron microscopy. Biomechanical properties were evaluated ex vivo via uniaxial tensile testing of rabbit corneas and human corneal lenticules.

Results

In vivo, extensive reshaping with fixation induced significant corneal flattening (6.55 ± 1.44 D at 1 month, stabilizing to 6.19 ± 1.12 D at 12 months; P 0.05). One-month safety evaluations were favorable, demonstrating normal corneal architecture and no cytotoxicity. Ex vivo biomechanics were significantly enhanced by the combined CXL-decorin treatment compared to CXL alone.

Conclusions

Combining mechanical molding with a CXL-decorin fixation protocol can achieve durable, non-ablative corneal reshaping, with the observed 12-month stability underpinned by enhanced biomechanical stiffness. This approach is a promising strategy for refractive correction and may have future applications in corneal ectatic diseases. Translational Relevance: This preclinical study validates the long-term safety and efficacy of a non-ablative, stromal-preserving, corneal-reshaping protocol, supporting its potential clinical translation for myopia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RiboflavinDecorinCross-Linking ReagentsCorneaPhotosensitizing AgentsAnimalsRabbitsCollagenUltraviolet RaysCorneal TopographyCorneal StromaHumansDisease Models, AnimalBiomechanical Phenomena

Substanzen

RiboflavinDecorinCross-Linking ReagentsCollagenPhotosensitizing Agents

Autor:innen und Institutionen

  • Department of Ophthalmology, Zhongshan Hospital, Fudan University, Shanghai, China.
  • Institute of Clinical Science, Zhongshan Hospital, Fudan University, Shanghai, China.
  • Department of Ophthalmology, West China Hospital, Sichuan University, Chengdu, China.

Zitieren

APA

Feng, C., Lin, X., Yuan, J., Wang, L., Ye, L., Feng, Q., Liu, S., Li, Z., Yuan, F., & Dai, J. (2025). Long-Term Corneal Reshaping Using Riboflavin–UVA Crosslinking Combined With Decorin in Rabbits. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.14.10.24

Vancouver

Feng C, Lin X, Yuan J, Wang L, Ye L, Feng Q, et al. Long-Term Corneal Reshaping Using Riboflavin–UVA Crosslinking Combined With Decorin in Rabbits. Translational Vision Science & Technology. 2025. doi:10.1167/tvst.14.10.24

BibTeX
@article{Feng2025,
  author = {Feng, Chenli and Lin, Xueqi and Yuan, Jiayue and Wang, Lingyan and Ye, Lin and Feng, Qianhong and Liu, Shichu and Li, Zheng and Yuan, Fei and Dai, Jinhui},
  title = {Long-Term Corneal Reshaping Using Riboflavin–UVA Crosslinking Combined With Decorin in Rabbits},
  journal = {Translational Vision Science & Technology},
  year = {2025},
  doi = {10.1167/tvst.14.10.24}
}
Kostenlos starten →