Fachartikel in der Zeitschrift Journal of Biophotonics, 2024. Verfasst von Hao Guo und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada. Hauptthemen laut MEDLINE: Monte Carlo Method, Spectrum Analysis, Raman, Fatty Liver, Phantoms, Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Research Nova Scotia.
Abstract (Originalsprache)
This study explores a combined strategy of Raman and reflectance spectroscopy for quantifying liver fat content and fat droplet size, crucial in assessing donor livers. By using Monte Carlo simulations and experimental setups with oil‐in‐water phantoms, our findings indicate that Raman scattering can solely differentiate between varying fat contents. At the same time, reflectance intensity is influenced by both fat content and oil droplet size, with a more pronounced sensitivity to fat droplet size. This study demonstrates the efficacy of combined Raman and reflectance spectroscopy in assessing liver steatosis and fat droplet size, potentially aiding in assessing donor livers for transplantation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada.
- Department of Medical Physics, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada.
- Fisheries and Oceans Canada, Bedford Institute of Oceanography, Dartmouth, Nova Scotia, Canada.
ORCID-Profile: Hao Guo, Kevin C Hewitt
Förderung
- Research Nova Scotia
Zitieren
APA
Guo, H., Zions, V. S., Law, B. A., & Hewitt, K. C. (2024). Potential of Raman‐Reflectance Combination in Quantifying Liver Steatosis and Fat Droplet Size: Evidence From Monte Carlo Simulations and Phantom Studies. Journal of Biophotonics. https://doi.org/10.1002/jbio.202400156
Vancouver
Guo H, Zions VS, Law BA, Hewitt KC. Potential of Raman‐Reflectance Combination in Quantifying Liver Steatosis and Fat Droplet Size: Evidence From Monte Carlo Simulations and Phantom Studies. Journal of Biophotonics. 2024. doi:10.1002/jbio.202400156
BibTeX
@article{Guo2024,
author = {Guo, Hao and Zions, Vanessa S and Law, Brent A and Hewitt, Kevin C},
title = {Potential of Raman‐Reflectance Combination in Quantifying Liver Steatosis and Fat Droplet Size: Evidence From Monte Carlo Simulations and Phantom Studies},
journal = {Journal of Biophotonics},
year = {2024},
doi = {10.1002/jbio.202400156}
}
EUVIMED