Application of a 3D Human Cornea‐Like Epithelium for Eye Irritation Assessment of Contact Lens Solutions
Journal of Applied Toxicology · 2025
DOI: 10.1002/jat.4820 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Toxicology, 2025. Verfasst von Xian He und 10 weiteren Autor:innen. Beteiligte Einrichtung: Zhejiang Institute of Medical Device Supervision and Testing, Hangzhou, China. Hauptthemen laut MEDLINE: Irritants, Epithelium, Corneal, Contact Lens Solutions, Toxicity Tests. Die Arbeit nennt 35 Literaturangaben. Gefördert von: Zhejiang Provincial Natural Science Foundation of China.
Abstract (Originalsprache)
Currently, medical device eye irritation testing relies on the Draize eye test in rabbits, which presents significant challenges regarding animal welfare and variations across laboratories. This research explores the application of the commercially available three‐dimensional reconstructed human corneal epithelial tissue (Skinovo‐Ocular) in eye irritation evaluation. The model is developed by culturing immortalized human corneal epithelial cells at a liquid‐air interface, resembling the morphology and induction of biological indicators found in human corneal tissue. We evaluated the eye irritation effect of 30 minimum reference chemicals according to OECD Performance Standards. The results revealed a sensitivity of 100%, specificity of 66.7%, and accuracy of 83.3%, indicating predictive performance comparable to other reference methods. Furthermore, we conducted analyses including trans‐epithelial electrical resistance, cytokine secretion, and histology, thereby enhancing our understanding of the mechanisms underlying eye irritation assessment in this model. Additionally, we tested various contact lens solutions and compared the results with rabbit in vivo experiments, demonstrating the model's potential for analyzing the eye irritation of mixtures. This model shows promise as an alternative for eye irritation analysis of medical devices, further reducing the reliance on experimental animals.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Zhejiang Institute of Medical Device Supervision and Testing, Hangzhou, China.
- NMPA Key Laboratory for Biomedical Optics, Hangzhou, China.
- Key Laboratory of Safety Evaluation of Medical Devices of Zhejiang Province, Hangzhou, China.
ORCID-Profile: Xian He
Förderung
- Zhejiang Provincial Natural Science Foundation of China
Zitieren
APA
He, X., Fang, L., Chen, X., Zhang, Z., Zhou, S., Qi, D., Weng, X., Lin, X., Gao, N., Hu, F., & Lu, X. (2025). Application of a 3D Human Cornea‐Like Epithelium for Eye Irritation Assessment of Contact Lens Solutions. Journal of Applied Toxicology. https://doi.org/10.1002/jat.4820
Vancouver
He X, Fang L, Chen X, Zhang Z, Zhou S, Qi D, et al. Application of a 3D Human Cornea‐Like Epithelium for Eye Irritation Assessment of Contact Lens Solutions. Journal of Applied Toxicology. 2025. doi:10.1002/jat.4820
BibTeX
@article{He2025,
author = {He, Xian and Fang, Li and Chen, Xianhua and Zhang, Ziyang and Zhou, Senting and Qi, Danning and Weng, Xu and Lin, Xinyi and Gao, Nana and Hu, Fei and Lu, Xin},
title = {Application of a 3D Human Cornea‐Like Epithelium for Eye Irritation Assessment of Contact Lens Solutions},
journal = {Journal of Applied Toxicology},
year = {2025},
doi = {10.1002/jat.4820}
}
EUVIMED