Development of Sensitive In Vitro Protocols for the Biocompatibility Testing of Medical Devices and Pharmaceuticals Intended for Contact with the Eyes: Acute Irritation and Phototoxicity Assessment
Alternatives to Laboratory Animals · 2024
DOI: 10.1177/02611929241270095 ↗Kurz gefasst
Fachartikel in der Zeitschrift Alternatives to Laboratory Animals, 2024. Verfasst von Peter Pôbiš und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Experimental Pharmacology and Toxicology (IEPT), Centre of Experimental Medicine (CEM), Slovak Academy of Sciences (SAS), Bratislava, Sl…. Hauptthemen laut MEDLINE: Animal Testing Alternatives, Eye. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: VEGA, APVV.
Abstract (Originalsprache)
This study introduces a novel in vitro methodology that employs the 3-D reconstructed tissue model, EpiOcular, to assess the irritation and phototoxicity potential of medical devices and drugs in contact with the eye. Our study evaluated diverse test materials, including medical devices, ophthalmological solutions and an experimental drug (cemtirestat), for their potential to cause eye irritation and phototoxicity. The protocols used in this study with the EpiOcular tissue model were akin to those used in the ultra-mildness testing of cosmetic formulations, which is challenging to predict with standard in vivo rabbit tests. To design these protocols, we leveraged experience gained from the validation project on the EpiDerm skin irritation test for medical devices (ISO 10993-23:2021) and the OECD TG 498 method for photo-irritation testing. The predictions were based on the tissue viability and inflammatory response, as determined by IL-1α release. By developing and evaluating these protocols for medical devices, we aimed to expand the applicability domain of the tests referred to in ISO 10993-23. This will contribute to the standardisation and cost-effective safety evaluation of ophthalmic products, while reducing reliance on animal testing in this field. The findings obtained from the EpiOcular model in the photo-irritation test could support its implementation in the testing strategies outlined in OECD TG 498.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Experimental Pharmacology and Toxicology (IEPT), Centre of Experimental Medicine (CEM), Slovak Academy of Sciences (SAS), Bratislava, Slovakia.
- Institute of Biochemistry and Microbiology, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Bratislava, Slovakia.
ORCID-Profile: Peter Pôbiš, Helena Kandárová
Förderung
- VEGA
- APVV
Zitieren
APA
Pôbiš, P., Kubalcová, J., Milasová, T., & Kandárová, H. (2024). Development of Sensitive In Vitro Protocols for the Biocompatibility Testing of Medical Devices and Pharmaceuticals Intended for Contact with the Eyes: Acute Irritation and Phototoxicity Assessment. Alternatives to Laboratory Animals. https://doi.org/10.1177/02611929241270095
Vancouver
Pôbiš P, Kubalcová J, Milasová T, Kandárová H. Development of Sensitive In Vitro Protocols for the Biocompatibility Testing of Medical Devices and Pharmaceuticals Intended for Contact with the Eyes: Acute Irritation and Phototoxicity Assessment. Alternatives to Laboratory Animals. 2024. doi:10.1177/02611929241270095
BibTeX
@article{Pbi2024,
author = {Pôbiš, Peter and Kubalcová, Júlia and Milasová, Tatiana and Kandárová, Helena},
title = {Development of Sensitive In Vitro Protocols for the Biocompatibility Testing of Medical Devices and Pharmaceuticals Intended for Contact with the Eyes: Acute Irritation and Phototoxicity Assessment},
journal = {Alternatives to Laboratory Animals},
year = {2024},
doi = {10.1177/02611929241270095}
}