EUVIMEDEUVIMED entdecken
Crossref

Reliability of the sonographic evaluation for cervical length and elastography with pelvic parameters in term pregnancy by experienced operators with varying levels of experience

Rapphon Sawaddisan, Noppasin Khwankaew, Ninlapa Pruksanusak iD, Thitima Suntharasaj, Chikasaem Suwanrath, Savitree Pranpanus, Chusana Petpichetchian, Manaphat Suksai, Natthicha Chainarong

International Journal of Gynecology & Obstetrics · 2024

DOI: 10.1002/ijgo.15363 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Gynecology & Obstetrics, 2024. Verfasst von Rapphon Sawaddisan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Faculty of Medicine, Prince of Songkla University, Hat Yai, Thailand. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Cervix Uteri, Ultrasonography, Prenatal, Cervical Length Measurement. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Faculty of Medicine, Prince of Songkla University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To assess the reliability of sonographic measurements of six cervical and pelvic parameters by three sonographers with varying levels of experience.

Methods

A cross‐sectional study was conducted in pregnant women with a gestational age of ≥39 weeks. Each pregnant woman was examined by two sonographers with different levels of experience. Six parameters were measured: cervical length (CL), cervical strain elastography (extrinsic type), posterior cervical angle (PCA), fetal head‐to‐perineum distance (FHPD), fetal head‐to‐pubic symphysis distance (FHSD), and angle of progression (AOP). Intra‐ and interobserver reliabilities were assessed using the intraclass correlation coefficient with a 95% confidence interval. Pearson pairwise correlation coefficients were used to analyze the correlation between the parameter values.

Results

In all, 66 pregnant women were enrolled in this study. We found excellent intraobserver reliability for measurements of CL, PCA, FHPD, FHSD, and AOP and good‐to‐excellent intraobserver reliability for cervical strain values in the cross‐sectional view of the endocervix in the internal os area and cross‐sectional view of the entire cervix in the internal os area. Interobserver reliability was excellent for all pelvic parameters, except for the FHPD. Strain values were moderate to excellent in the area of the internal os. A significant negative correlation between CL and strain values at the internal os was observed.

Conclusions

Pelvic parameters, except for FHPD, have excellent intra‐ and interobserver reliabilities. The high reproducibility of CL and cervical strain elastography at the internal os level, with a negative correlation between these two parameters, may play an important role in predicting successful induction of labor.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesCervix UteriUltrasonography, PrenatalCervical Length MeasurementHumansFemalePregnancyCross-Sectional StudiesAdultReproducibility of ResultsObserver VariationPelvisYoung AdultClinical CompetenceGestational Age

Stichwörter der Autor:innen

cervical elastographypelvic parametersreliabilityterm pregnancy

Autor:innen und Institutionen

  • Department of Obstetrics and Gynecology, Faculty of Medicine, Prince of Songkla University, Hat Yai, Thailand.

ORCID-Profile: Ninlapa Pruksanusak

Förderung

  • Faculty of Medicine, Prince of Songkla University

Zitieren

APA

Sawaddisan, R., Khwankaew, N., Pruksanusak, N., Suntharasaj, T., Suwanrath, C., Pranpanus, S., Petpichetchian, C., Suksai, M., & Chainarong, N. (2024). Reliability of the sonographic evaluation for cervical length and elastography with pelvic parameters in term pregnancy by experienced operators with varying levels of experience. International Journal of Gynecology & Obstetrics. https://doi.org/10.1002/ijgo.15363

Vancouver

Sawaddisan R, Khwankaew N, Pruksanusak N, Suntharasaj T, Suwanrath C, Pranpanus S, et al. Reliability of the sonographic evaluation for cervical length and elastography with pelvic parameters in term pregnancy by experienced operators with varying levels of experience. International Journal of Gynecology & Obstetrics. 2024. doi:10.1002/ijgo.15363

BibTeX
@article{Sawaddisan2024,
  author = {Sawaddisan, Rapphon and Khwankaew, Noppasin and Pruksanusak, Ninlapa and Suntharasaj, Thitima and Suwanrath, Chikasaem and Pranpanus, Savitree and Petpichetchian, Chusana and Suksai, Manaphat and Chainarong, Natthicha},
  title = {Reliability of the sonographic evaluation for cervical length and elastography with pelvic parameters in term pregnancy by experienced operators with varying levels of experience},
  journal = {International Journal of Gynecology & Obstetrics},
  year = {2024},
  doi = {10.1002/ijgo.15363}
}
Kostenlos starten →