Evaluation of Non‐Compressive Transvaginal Cervical Elastography as a Quantitative Imaging Biomarker in Pregnancy
Journal of Ultrasound in Medicine · 2024
DOI: 10.1002/jum.16331 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Ultrasound in Medicine, 2024. Verfasst von Matthew K Janssen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Maternal Fetal Medicine Research Program, Department of Obstetrics and Gynecology, The University of Pennsylvania Perelman School of Medicine, Philad…. Hauptthemen laut MEDLINE: Cervix Uteri, Elasticity Imaging Techniques. Die Arbeit nennt 43 Literaturangaben.
Abstract (Originalsprache)
Objectives
Non‐compressive strain elastography has been proposed as a novel quantitative imaging biomarker for assessing the structure and function of the cervix. The current study aims to assess the repeatability, and intra‐ and inter‐observer reliability of transvaginal non‐compressive cervical strain elastography in a clinical setting.
Methods
We conducted a dual‐phase single‐center prospective feasibility study of singleton gestations >16‐weeks gestation that required a clinically‐indicated transvaginal ultrasound. Each study participant, n = 43 in phase 1 and n = 13 in phase 2, had elastography performed by two trained observers that each performed multiple image acquisitions. We performed a multivariable regression to adjust for changes in clinical characteristics between study phases and calculated the repeatability coefficients, limits of agreement, and intraclass correlations for each quantitative elastography parameter. We compared quantitative elastography parameters to cervical length measurements, acquired from the same images.
Results
The repeatability coefficients and percent limits of agreement were wide for all of the quantitative elastography parameters, demonstrating poor repeatability . Intraclass correlation coefficients were poor–moderate for both intra‐observer (0.31–0.77) and inter‐observer reliability (0.35–0.77) in both study phases, while cervical length showed excellent reliability with intraclass correlations consistently >0.90.
Conclusions
Non‐compressive transvaginal strain cervical elastography did not demonstrate adequate repeatability or reliability. Our results highlight the importance of rigorously assessing novel quantitative imaging biomarkers before clinical application.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Maternal Fetal Medicine Research Program, Department of Obstetrics and Gynecology, The University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania, USA.
- Center for Epidemiology and Biostatistics, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
- Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.
ORCID-Profile: Matthew K Janssen
Zitieren
APA
Janssen, M. K., Koelper, N., Weatherby, M., Werth, C., & Schwartz, N. (2024). Evaluation of Non‐Compressive Transvaginal Cervical Elastography as a Quantitative Imaging Biomarker in Pregnancy. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.16331
Vancouver
Janssen MK, Koelper N, Weatherby M, Werth C, Schwartz N. Evaluation of Non‐Compressive Transvaginal Cervical Elastography as a Quantitative Imaging Biomarker in Pregnancy. Journal of Ultrasound in Medicine. 2024. doi:10.1002/jum.16331
BibTeX
@article{Janssen2024,
author = {Janssen, Matthew K and Koelper, Nathan and Weatherby, Michele and Werth, Christina and Schwartz, Nadav},
title = {Evaluation of Non‐Compressive Transvaginal Cervical Elastography as a Quantitative Imaging Biomarker in Pregnancy},
journal = {Journal of Ultrasound in Medicine},
year = {2024},
doi = {10.1002/jum.16331}
}
EUVIMED