EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A prospective randomized crossover manikin study comparing GlideScope® video laryngoscopy and direct laryngoscopy for impacted fish bone removal in a simulated difficult airway

Matthew Chi Yeung Lung, Wai Yin Leung, Chun Tat Lui

Hong Kong Journal of Emergency Medicine · 2026-04 · 33 (2)

DOI: 10.1002/hkj2.70092 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hong Kong Journal of Emergency Medicine, online erschienen am 19.03.2026. Verfasst von Matthew Chi Yeung Lung und 2 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Fish bone ingestion is a common emergency presentation. Direct laryngoscopy (DL) is the conventional bedside technique, but it can be limited in anatomically challenging airways. Video laryngoscopy (VL) improves glottic visualization for intubation, yet its role in foreign body retrieval is unclear. Because difficult airway features (e.g., restricted mouth opening, cervical spine immobility) occur in the general population and may complicate retrieval, we compared VL and DL in a simulated difficult airway model.

Methods

In this prospective, multicenter, randomized crossover manikin study, 56 emergency physicians (24 specialists, 32 non‐specialists) performed two timed retrieval attempts (maximum 120 s each) on a manikin fitted with a cervical collar. Each attempt required the removal of three simulated fish bones (vallecula, left pyriform sinus, post‐cricoid) using Magill forceps. Device order was block‐randomized and stratified by specialist status. The primary outcome was complete retrieval success. Secondary outcomes included retrieval times, Cormack‐Lehane grade, ease of use, and device preference.

Results

VL achieved higher success than DL (83.9% vs. 66.1%; p = 0.013). Adjusted analysis favored VL (adjusted odds ratio 3.10, 95% CI 0.90–10.71; p = 0.073). VL yielded superior glottic views (Grade 1: 55.4% vs. 12.5%; p < 0.001), was rated easier ( p < 0.001), and was preferred by most operators (57.1%). Total retrieval times were similar, but VL was slower to first retrieval (17.5 vs. 13.0 s; p = 0.001).

Conclusions

In a simulated difficult airway, VL improved success, visualization, and operator preference; slower initial retrieval suggests a need for instrument optimization and targeted training.

Zitieren

APA

Lung, M. C. Y., Leung, W. Y., & Lui, C. T. (2026). A prospective randomized crossover manikin study comparing GlideScope® video laryngoscopy and direct laryngoscopy for impacted fish bone removal in a simulated difficult airway. Hong Kong Journal of Emergency Medicine, 33(2). https://doi.org/10.1002/hkj2.70092

Vancouver

Lung MCY, Leung WY, Lui CT. A prospective randomized crossover manikin study comparing GlideScope® video laryngoscopy and direct laryngoscopy for impacted fish bone removal in a simulated difficult airway. Hong Kong Journal of Emergency Medicine. 2026;33(2). doi:10.1002/hkj2.70092

BibTeX
@article{Lung2026,
  author = {Lung, Matthew Chi Yeung and Leung, Wai Yin and Lui, Chun Tat},
  title = {A prospective randomized crossover manikin study comparing GlideScope® video laryngoscopy and direct laryngoscopy for impacted fish bone removal in a simulated difficult airway},
  journal = {Hong Kong Journal of Emergency Medicine},
  year = {2026},
  volume = {33},
  number = {2},
  doi = {10.1002/hkj2.70092}
}
Kostenlos starten →