EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparison of Macintosh Laryngoscope, King Vision®, VividTrac®, AirAngel Blade®, and a Custom-Made 3D-Printed Video Laryngoscope for Difficult and Normal Airways in Mannequins by Novices—A Non-Inferiority Trial

Viktor Bacher, Márton Németh, Szilárd Rendeki, Balázs Tornai, Martin Rozanovic iD, Andrea Pankaczi, János Oláh, József Farkas, Melánia Chikhi, Ádám Schlégl iD, Péter Maróti iD, Bálint Nagy

Journal of Clinical Medicine · 30.05.2024 · 13 (11) · 3213

DOI: 10.3390/jcm13113213 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 30.05.2024. Verfasst von Viktor Bacher und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Intensive Medicine, Medical School, University of Pecs, H-7624 Pecs, Hungary. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research, Development and Innovation Fund of Hungary, University of Pécs.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Endotracheal intubation (ETI) is a cornerstone of airway management. The gold standard device for ETI is still the direct laryngoscope (DL). However, video laryngoscopes (VLs) are now also widely available and have several proven advantages. The VL technique has been included in the major airway management guidelines. During the COVID-19 pandemic, supply chain disruption has raised demand for 3D-printed medical equipment, including 3D-printed VLs. However, studies on performance are only sparsely available; thus, we aimed to compare 3D-printed VLs to the DL and other VLs made with conventional manufacturing technology.

Methods

Forty-eight medical students were recruited to serve as novice users. Following brief, standardized training, students executed ETI with the DL, the King Vision® (KV), the VividTrac® (VT), the AirAngel Blade® (AAB), and a custom-made 3D-printed VL (3DVL) on the Laerdal® airway management trainer in normal and difficult airway scenarios. We evaluated the time to and proportion of successful intubation, the best view of the glottis, esophageal intubation, dental trauma, and user satisfaction.

Results

The KV and VT are proved to be superior (p < 0.05) to the DL in both scenarios. The 3DVL’s performance was similar (p > 0.05) or significantly better than that of the DL and mainly non-inferior (p > 0.05) compared to the KV and VT in both scenarios. Regardless of the scenario, the AAB proved to be inferior (p < 0.05) even to the DL in the majority of the variables. The differences between the devices were more pronounced in the difficult airway scenario. The user satisfaction scores were in concordance with the aforementioned performance of the scopes.

Conclusions

Based upon our results, we cannot recommend the AAB over the DL, KV, or VT. However, as the 3DVL showed, 3D printing indeed can provide useful or even superior VLs, but prior to clinical use, meticulous evaluation might be recommended.

Schlagwörter

Stichwörter der Autor:innen

3D printingAirAngel Blade®King Vision®VividTrac®airway managementcustom-made deviceendotracheal intubationvideolaryngoscope

Autor:innen und Institutionen

  • Department of Anesthesiology and Intensive Medicine, Medical School, University of Pecs, H-7624 Pecs, Hungary.
  • Medical Skills Education and Innovation Centre, Medical School, University of Pécs, H-7624 Pecs, Hungary.
  • Department of Anatomy, Medical School, University of Pécs, H-7624 Pecs, Hungary.
  • Department of Orthopedics, Medical School, University of Pécs, H-7624 Pecs, Hungary.
  • 3D Printing & Visualization Centre, Medical School, University of Pécs, H-7624 Pecs, Hungary.

ORCID-Profile: Martin Rozanovic, Ádám Schlégl, Péter Maróti

Förderung

  • National Research, Development and Innovation Fund of Hungary
  • University of Pécs

Zitieren

APA

Bacher, V., Németh, M., Rendeki, S., Tornai, B., Rozanovic, M., Pankaczi, A., Oláh, J., Farkas, J., Chikhi, M., Schlégl, Á., Maróti, P., & Nagy, B. (2024). Comparison of Macintosh Laryngoscope, King Vision®, VividTrac®, AirAngel Blade®, and a Custom-Made 3D-Printed Video Laryngoscope for Difficult and Normal Airways in Mannequins by Novices—A Non-Inferiority Trial. Journal of Clinical Medicine, 13(11), 3213. https://doi.org/10.3390/jcm13113213

Vancouver

Bacher V, Németh M, Rendeki S, Tornai B, Rozanovic M, Pankaczi A, et al. Comparison of Macintosh Laryngoscope, King Vision®, VividTrac®, AirAngel Blade®, and a Custom-Made 3D-Printed Video Laryngoscope for Difficult and Normal Airways in Mannequins by Novices—A Non-Inferiority Trial. Journal of Clinical Medicine. 2024;13(11):3213. doi:10.3390/jcm13113213

BibTeX
@article{Bacher2024,
  author = {Bacher, Viktor and Németh, Márton and Rendeki, Szilárd and Tornai, Balázs and Rozanovic, Martin and Pankaczi, Andrea and Oláh, János and Farkas, József and Chikhi, Melánia and Schlégl, Ádám and Maróti, Péter and Nagy, Bálint},
  title = {Comparison of Macintosh Laryngoscope, King Vision®, VividTrac®, AirAngel Blade®, and a Custom-Made 3D-Printed Video Laryngoscope for Difficult and Normal Airways in Mannequins by Novices—A Non-Inferiority Trial},
  journal = {Journal of Clinical Medicine},
  year = {2024},
  volume = {13},
  number = {11},
  pages = {3213},
  doi = {10.3390/jcm13113213}
}
Kostenlos starten →