EUVIMEDEUVIMED entdecken
VergleichsstudieMetaanalyseSystematische Übersicht

Camera‐based near‐infrared autofluorescence versus visual identification in total thyroidectomy for parathyroid function preservation: Systematic review and meta‐analysis of randomized clinical trials

Luca Canali iD, Marika D Russell, Anthea Sistovaris, Amr H Abdelhamid Ahmed iD, Michael Otremba, Hien T Tierney, Frédéric Triponez, Fares Benmiloud, Giuseppe Spriano, Giuseppe Mercante, Gregory W Randolph

Head & Neck · 2025-01 · 47 (1) · 225-234

DOI: 10.1002/hed.27900 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Head & Neck, online erschienen am 05.08.2024. Verfasst von Luca Canali und 10 weiteren Autor:innen. Beteiligte Einrichtung: Division of Thyroid and Parathyroid Endocrine Surgery, Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, Har…. Hauptthemen laut MEDLINE: Hypocalcemia, Optical Imaging, Parathyroid Glands, Thyroidectomy. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 37 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Hypocalcemia is the most common postoperative complication of total thyroidectomy. Near‐infrared autofluorescence (NIRAF) technology is a surgical adjunct that has been increasingly utilized with the aim of preventing postoperative hypocalcemia, but its clinical benefits have not yet been firmly established. The aim of this study was to assess the clinical benefit of utilizing NIRAF technology in patients undergoing total thyroidectomy.

Methods

A systematic review and meta‐analysis of randomized clinical trials was performed according to PRISMA guidelines.

Results

Seven randomized clinical trials with 1437 patients (318 males, 22.13%) undergoing total thyroidectomy were included for analysis. Risk of postoperative hypocalcemia was reduced in the NIRAF arm (RR, 0.65; 95%CI, 0.50–0.84). Use of NIRAF was also associated with a reduction in the risk of permanent parathyroid dysfunction (RR, 0.46; 95%CI, 0.22–0.95) and inadvertent parathyroid gland resection (RR, 0.40; 95%CI, 0.26–0.60).

Conclusions

We present a systematic review and meta‐analysis of randomized clinical trials examining the impact of NIRAF technology on preservation of parathyroid function. Our results suggest that use of camera‐based NIRAF technology reduces the risk of postoperative hypocalcemia, permanent parathyroid dysfunction, and inadvertent parathyroid gland resection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HypocalcemiaOptical ImagingParathyroid GlandsThyroidectomyHumansPostoperative ComplicationsRandomized Controlled Trials as TopicSpectroscopy, Near-Infrared

Stichwörter der Autor:innen

near‐infrared autofluorecenceparathyroid preservationpostoperative hypocalcemiarandomized clinical trialthyroid surgery

Autor:innen und Institutionen

  • Division of Thyroid and Parathyroid Endocrine Surgery, Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, Massachusetts, USA.
  • Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Italy.
  • Otorhinolaryngology Unit, IRCCS Humanitas Research Hospital, Rozzano, Italy.
  • Thoracic and Endocrine Surgery, Department of Surgery, Faculty of Medicine of Geneva, University Hospitals, Geneva, Switzerland.
  • Endocrine Surgery Unit, Hôpital Européen Marseille, Marseille, France.
  • Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.

ORCID-Profile: Luca Canali, Amr H Abdelhamid Ahmed

Zitieren

APA

Canali, L., Russell, M. D., Sistovaris, A., Abdelhamid Ahmed, A. H., Otremba, M., Tierney, H. T., Triponez, F., Benmiloud, F., Spriano, G., Mercante, G., & Randolph, G. W. (2025). Camera‐based near‐infrared autofluorescence versus visual identification in total thyroidectomy for parathyroid function preservation: Systematic review and meta‐analysis of randomized clinical trials. Head & Neck, 47(1), 225-234. https://doi.org/10.1002/hed.27900

Vancouver

Canali L, Russell MD, Sistovaris A, Abdelhamid Ahmed AH, Otremba M, Tierney HT, et al. Camera‐based near‐infrared autofluorescence versus visual identification in total thyroidectomy for parathyroid function preservation: Systematic review and meta‐analysis of randomized clinical trials. Head & Neck. 2025;47(1):225-234. doi:10.1002/hed.27900

BibTeX
@article{Canali2025,
  author = {Canali, Luca and Russell, Marika D and Sistovaris, Anthea and Abdelhamid Ahmed, Amr H and Otremba, Michael and Tierney, Hien T and Triponez, Frédéric and Benmiloud, Fares and Spriano, Giuseppe and Mercante, Giuseppe and Randolph, Gregory W},
  title = {Camera‐based near‐infrared autofluorescence versus visual identification in total thyroidectomy for parathyroid function preservation: Systematic review and meta‐analysis of randomized clinical trials},
  journal = {Head & Neck},
  year = {2025},
  volume = {47},
  number = {1},
  pages = {225--234},
  doi = {10.1002/hed.27900}
}
Kostenlos starten →