Utilisation of Near Infrared Autofluorescence in Parathyroid Identification During Thyroidectomy: A Systematic Review and Meta‐Analysis of Randomised Controlled Trials
Clinical Otolaryngology · 2025
DOI: 10.1111/coa.14313 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Clinical Otolaryngology, 2025. Verfasst von Azfar Javed und 9 weiteren Autor:innen. Beteiligte Einrichtung: Queen Elizabeth Hospital, University Hospital Birmingham NHS Foundation Trust, Birmingham, UK. Hauptthemen laut MEDLINE: Thyroidectomy, Hypoparathyroidism, Parathyroid Glands, Optical Imaging. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 39 Literaturangaben.
Abstract (Originalsprache)
Objective
Unintentional parathyroid gland resection during total thyroidectomy can result in permanent hypoparathyroidism and lifelong replacement therapy. Near infrared autofluorescence (NIRAF) imaging may aid intraoperative identification and preservation of the parathyroid glands. This article aims to review NIRAF's effectiveness in the prevention of post‐operative hypoparathyroidism.
Design
Systematic review and meta‐analysis reported according to PRISMA guidelines.
Methods
The electronic databases of MEDLINE, Embase and Cochrane were searched in September 2024. Included articles were randomised controlled trials (RCTs) that studied the use of NIRAF vs. dissection with no intraoperative aids in thyroidectomy. Meta‐analysis was performed using a random‐effects model. Primary outcomes were postoperative hypocalcaemia and permanent hypoparathyroidism.
Results
Eight RCTs were included in the final analysis, comprising 1620 patients. Meta‐analysis revealed patients undergoing thyroidectomy using NIRAF had a reduced risk of both post‐operative hypocalcaemia (OR 0.56, 95% CI: 0.36–0.89, p = 0.01) and persistent hypoparathyroidism (OR 0.44, 95% CI: 0.22–0.89, p = 0.02).
Conclusions
NIRAF use in thyroidectomy reduces the risk of post‐operative hypocalcaemia and post‐operative hypoparathyroidism.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Queen Elizabeth Hospital, University Hospital Birmingham NHS Foundation Trust, Birmingham, UK.
ORCID-Profile: Keshav Kumar Gupta
Zitieren
APA
Javed, A., Alburaiki, A., Sharma, N., De, M., Garas, G., Ahmad, I., Nankivell, P., Sonsale, A., Fussey, J., & Gupta, K. K. (2025). Utilisation of Near Infrared Autofluorescence in Parathyroid Identification During Thyroidectomy: A Systematic Review and Meta‐Analysis of Randomised Controlled Trials. Clinical Otolaryngology. https://doi.org/10.1111/coa.14313
Vancouver
Javed A, Alburaiki A, Sharma N, De M, Garas G, Ahmad I, et al. Utilisation of Near Infrared Autofluorescence in Parathyroid Identification During Thyroidectomy: A Systematic Review and Meta‐Analysis of Randomised Controlled Trials. Clinical Otolaryngology. 2025. doi:10.1111/coa.14313
BibTeX
@article{Javed2025,
author = {Javed, Azfar and Alburaiki, Abdullah and Sharma, Neil and De, Mriganka and Garas, George and Ahmad, Ijaz and Nankivell, Paul and Sonsale, Anita and Fussey, Jonathan and Gupta, Keshav Kumar},
title = {Utilisation of Near Infrared Autofluorescence in Parathyroid Identification During Thyroidectomy: A Systematic Review and Meta‐Analysis of Randomised Controlled Trials},
journal = {Clinical Otolaryngology},
year = {2025},
doi = {10.1111/coa.14313}
}
EUVIMED