Improving the Quality of Brain PET Images Using MR ‐Guided PET Reconstruction Technique With Integrated PET / MR
Human Brain Mapping · 2025
DOI: 10.1002/hbm.70292 ↗Kurz gefasst
Fachartikel in der Zeitschrift Human Brain Mapping, 2025. Verfasst von Hongda Shao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China. Hauptthemen laut MEDLINE: Positron-Emission Tomography, Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
To evaluate the performance of an MR‐guided PET reconstruction method in enhancing the image quality of brain PET images acquired with an integrated PET/MR system. We implemented an MR‐guided PET reconstruction (MRg) algorithm in an integrated PET/MR system and conducted both phantom and clinical studies. The PET images of a Hoffman phantom were reconstructed using the MRg algorithm and routine Ordered Subsets Expectation Maximization (OSEM) algorithm. Image quality metrics were calculated to investigate the dose effects, number of iterations, and penalization factor ( β ). In the clinical study, the PET images of 30 patients without brain lesions, two patients with diffuse large B cell lymphoma (DLBCL), 18 patients with Parkinson's disease (PD) and one patient with cavernous angioma were reconstructed using MRg and OSEM, respectively. Qualitative and quantitative assessments were performed. In the phantom study, MRg images demonstrated improved image quality metrics (higher contrast and lower variability) compared to conventional OSEM, particularly at lower doses. The penalization factor maximized the advantages of MRg. In the clinical study of patients without brain lesions, MRg significantly outperformed OSEM in image quality evaluation. For patients with DLBCL, the lesions' signal/contrast‐to‐background/noise ratios exhibited significant improvements using the MRg. For patients with PD, the standardized uptake value ratio and contrast‐to‐noise ratio of bilateral putamen were significantly improved by MRg. The MRg has convincingly demonstrated significant advantages over the conventional OSEM in brain PET images, indicating great potential in clinical routines for brain PET/MR examinations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Nuclear Medicine, Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
- Central Research Institute, UIH Group, Shanghai, China.
ORCID-Profile: Hongda Shao, Jianjun Liu
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Shao, H., Huang, G., Wang, Y., Zhang, Y., Xue, Q., Hao, J., & Liu, J. (2025). Improving the Quality of Brain PET Images Using MR ‐Guided PET Reconstruction Technique With Integrated PET / MR. Human Brain Mapping. https://doi.org/10.1002/hbm.70292
Vancouver
Shao H, Huang G, Wang Y, Zhang Y, Xue Q, Hao J, et al. Improving the Quality of Brain PET Images Using MR ‐Guided PET Reconstruction Technique With Integrated PET / MR. Human Brain Mapping. 2025. doi:10.1002/hbm.70292
BibTeX
@article{Shao2025,
author = {Shao, Hongda and Huang, Gan and Wang, Yue and Zhang, Yan and Xue, Qiaoyi and Hao, Jiaxin and Liu, Jianjun},
title = {Improving the Quality of Brain PET Images Using MR ‐Guided PET Reconstruction Technique With Integrated PET / MR},
journal = {Human Brain Mapping},
year = {2025},
doi = {10.1002/hbm.70292}
}
EUVIMED