Cross‐Modality Image Translation of 3 Tesla Magnetic Resonance Imaging to 7 Tesla Using Generative Adversarial Networks
Human Brain Mapping · 15.06.2025 · 46 (9)
DOI: 10.1002/hbm.70246 ↗Kurz gefasst
Fachartikel in der Zeitschrift Human Brain Mapping, online erschienen am 22.06.2025. Verfasst von Eduardo Diniz und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Psychology, Carnegie Mellon University, Pennsylvania, USA. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Neural Networks, Computer, Neuroimaging. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 103 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIH HHS, CNPq, National Institutes of Health.
Abstract (Originalsprache)
The rapid advancements in magnetic resonance imaging (MRI) technology have precipitated a new paradigm wherein cross‐modality data translation across diverse imaging platforms, field strengths, and different sites is increasingly challenging. This issue is particularly accentuated when transitioning from 3 Tesla (3T) to 7 Tesla (7T) MRI systems. This study proposes a novel solution to these challenges using generative adversarial networks (GANs)—specifically, the CycleGAN architecture—to create synthetic 7T images from 3T data. Employing a dataset of 1112 and 490 unpaired 3T and 7T MR images, respectively, we trained a 2‐dimensional (2D) CycleGAN model, evaluating its performance on a paired dataset of 22 participants scanned at 3T and 7T. Independent testing on 22 distinct participants affirmed the model's proficiency in accurately predicting various tissue types, encompassing cerebral spinal fluid, gray matter, and white matter. Our approach provides a reliable and efficient methodology for synthesizing 7T images, achieving a median Dice coefficient of 83.62% for cerebral spinal fluid (CSF), 81.42% for gray matter (GM), and 89.75% for White Matter (WM), while the corresponding median Percentual Area Differences (PAD) were 6.82%, 7.63%, and 4.85% for CSF, GM, and WM, respectively, in the testing dataset, thereby aiding in harmonizing heterogeneous datasets. Furthermore, it delineates the potential of GANs in amplifying the contrast‐to‐noise ratio (CNR) from 3T, potentially enhancing the diagnostic capability of the images. While acknowledging the risk of model overfitting, our research underscores a promising progression toward harnessing the benefits of 7T MR systems in research investigations while preserving compatibility with existing 3T MR data. This work was previously presented at the ISMRM 2021 conference.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Psychology, Carnegie Mellon University, Pennsylvania, USA.
- Department of Bioengineering, University of Pittsburgh, Pennsylvania, USA.
- Department of Psychiatry, University of Pittsburgh, Pennsylvania, USA.
ORCID-Profile: Tales Santini, Tamer S Ibrahim
Förderung
- NIH HHS
- CNPq
- National Institutes of Health
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
Zitieren
APA
Diniz, E., Santini, T., Karim, H., Aizenstein, H. J., & Ibrahim, T. S. (2025). Cross‐Modality Image Translation of 3 Tesla Magnetic Resonance Imaging to 7 Tesla Using Generative Adversarial Networks. Human Brain Mapping, 46(9). https://doi.org/10.1002/hbm.70246
Vancouver
Diniz E, Santini T, Karim H, Aizenstein HJ, Ibrahim TS. Cross‐Modality Image Translation of 3 Tesla Magnetic Resonance Imaging to 7 Tesla Using Generative Adversarial Networks. Human Brain Mapping. 2025;46(9). doi:10.1002/hbm.70246
BibTeX
@article{Diniz2025,
author = {Diniz, Eduardo and Santini, Tales and Karim, Helmet and Aizenstein, Howard J and Ibrahim, Tamer S},
title = {Cross‐Modality Image Translation of 3 Tesla Magnetic Resonance Imaging to 7 Tesla Using Generative Adversarial Networks},
journal = {Human Brain Mapping},
year = {2025},
volume = {46},
number = {9},
doi = {10.1002/hbm.70246}
}
EUVIMED